Configuring
6.2 Configuration via PROFIBUS
4. Optional: Switch to the device view and delete an existing module (e.g. "Reader_1") if
necessary and drag a suitable module from the hardware catalog into the corresponding
module column.
5. Connect the communication module with the controller.
6. Configure the communication module (e.g. PROFIBUS address).
7. Assign parameters to the communication module (e.g. module parameters).
8. Save the configuration, or download it to the PROFIBUS controller.
Parameter assignment with the device configuration
You can set the basic parameters of the communication module, as well as the parameters
of the readers connected to the communication module, using the properties window of the
communication module. You can set all module-specific parameters using the following
parameter groups.
"Web Based Management" parameter group
You can start Web Based Management in this parameter group.
Table 6- 1
Parameters of the "Web Based Management" parameter group
Parameter
IP address
Web Based Manage-
ment
"Module parameters" parameter group of the communication module
In this parameter group, you can configure all module-specific parameters of the
communication module.
Table 6- 2
Parameters in the "Module parameters" parameter group
Parameter
User Mode
52
Description
Enter the IP address of the communication module in this input box. This is required to start the
Web Based Management of the communication module.
Start Web Based Management of the communication module.
Web Based Management (WBM) offers extensive functions for configuring the communication
module.
Requirement: The communication module is connected to a PC/PG via the Ethernet interface.
Note that WBM can only be started when the IP address stored in the project has been assigned
to the communication module. This means that the TIA configuration must be loaded into the
SIMATIC controller.
Parameter value
Ident profile/RFID stand-
ard profile
Default value
Description
Ident profile/RFID
With this parameter, you select the block:
standard profile
Operating Instructions, 12/2019, C79000-G8976-C578-01
Ident profile/RFID standard profile
SIMATIC RF166C