Siemens SIMATIC RF1000 Operating Instructions Manual

Hide thumbs Also See for SIMATIC RF1000:
Table of Contents

Advertisement

Quick Links

SIMATIC Ident
RFID systems
SIMATIC RF1000
Operating Instructions
05/2023
C79000-G8976-C432-10
Introduction
Security recommendations
Description
Installation
Connecting
Commissioning
Programming
Demo application
Technical specifications
Dimension drawings
Appendix
Service & Support
1
2
3
4
5
6
7
8
9
10
A
B

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC RF1000

  • Page 1 Introduction Security recommendations Description SIMATIC Ident Installation RFID systems SIMATIC RF1000 Connecting Commissioning Operating Instructions Programming Demo application Technical specifications Dimension drawings Appendix Service & Support 05/2023 C79000-G8976-C432-10...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Programming via the RS232 interface (using the Freeport protocol)........53 7.3.1 Implementation of the commands ..................54 7.3.2 Commands ........................55 7.3.2.1 syscmd_reset ........................55 7.3.2.2 syscmd_get_info........................ 56 7.3.2.3 syscmd_get_boot_status ....................56 7.3.2.4 syscmd_set_port........................ 57 SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 4 User interface of the demo application ................69 Creating a custom application .................... 72 Technical specifications ........................79 Technical specifications of SIMATIC RF1000 ................ 79 Technical specifications, RF1100T Configuration Card ............81 Technical specifications of the license cards ................ 82 Technical specifications of table/wall housing ..............
  • Page 5: Introduction

    SIMATIC ®, SIMATIC RF ® and MOBY ® Orientation in the documentation Detailed information on creating and customizing configurations as well as their transfer to the SIMATIC RF1000 reader is available in the configuration manual "SIMATIC RF1000 (https:// support.industry.siemens.com/cs/ww/en/ps/24224/man)". The manuals of the relevant SIMATIC Ident products (e.g. SIMATIC RF170C) on the Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/14970/...
  • Page 6 Do not dispose of the products at public disposal sites. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste or your Siemens representative. Note the different country-specific regulations.
  • Page 7: Security Recommendations

    Certificates and keys • Before sending the device to Siemens for repair, restore the factory settings. • Make sure that the data stored on the transponders/cards is encrypted and that decryption/ encryption of the data takes place on the connected devices.
  • Page 8: Security Information

    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure...
  • Page 9: Cell Protection Concept

    SIMATIC ET200SP MV500 XC-200 SIMATIC SIRIUS ACT SIMATIC RF188CI SIMATIC RF650R RF220R Cell 1 Cell 2 Cell 3 Industrial Ethernet PROFINET Safety Figure 2-1 Schematic display of a cell protection concept for the RF1000 readers SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 10 Security recommendations 2.2 Cell protection concept SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 11: Description

    USB interface is not openly accessible after installation. Figure 3-1 Product photos of the SIMATIC RF1000 reader The SIMATIC RF1000 readers are designed for connection to a Windows computer. Alternatively, they can also be operated on a Linux-based system. SIMATIC RF1000...
  • Page 12 OEM version. This reader variant is identical to the RF1070R, but is supplied with a neutral front foil. A separate foil can be created as an alternative. Interface-specific programming The Siemens support site "Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/view/109741590)" provides access functions for the readers in the form of DLL files for Windows, as well as a demo application.
  • Page 13: Connection Options And Supported Transponders

    6GT2891- 6GT2891 6GT2891 scope of delivery scope of delivery 4UH20 -4UH20 -2UH30 A connection via other applications is possible. You can find additional information on this in the section "Programming via the RS232 interface". SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 14 Serial number Serial number Serial number FeliCa Serial number Serial number Serial number EM4100/EM4102, Casi-Rusco Serial number EM4450/EM4550, EKS ✓ HITAG 1, HITAG S ✓ HITAG 2 Serial number Keri Serial number SecuraKey Serial number SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 15 14443/15693. For transponders with two integrated chips (125 kHz / 13.56 MHz), you must ensure which chip is addressed via the reader configuration. SIMATIC RF1000 readers can also recognize multiple transponders that are simultaneously located in the antenna field. You can find information on selecting multiple transponders in the section "vhl_select (Page 43)".
  • Page 16 Description 3.2 Connection options and supported transponders SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 17: Installation

    This is due to deviations in card antennas, card IC parameters and RFID interface parameters, which can influence both energy transfer and the quality of the data transfer. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 18 Do not try to repair the reader in case of a problem. Repair and maintenance work must only be carried out by qualified personnel. Contact Siemens Support in case of repair or maintenance problems. For more information, refer to the section "Service & Support".
  • Page 19 Replace the pre-installed USB cable with the supplied RS232 cable as described in the section "Connecting (Page 25)". 2. Optionally when using the cleanroom cover: Drill condensate holes below the installation opening. Figure 4-1 Condensate holes SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 20 Ensure that the reader housing is flush with the base and that the circumferential gap is < 0.5 Figure 4-2 In-wall installation of the SIMATIC RF1000 reader 7. Optionally when using the reader in a cleanroom: Apply a silicone joint on the front between the reader edge or the cleanroom cover and the surface or the wall.
  • Page 21 Place the card holder on the side of the reader housing and press it over the reader front so that the card holder locks in place. Note that you cannot use the card holder in combination with the cleanroom cover. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 22 6. Fasten the reader in the table/wall housing by installing the reader in the housing using the 4x Torx screws (max. 1.5 Nm) and the four inside mounting holes of the table/wall housing. Figure 4-5 Installing the reader in the table/wall housing SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 23 (with the cutout for the connecting cable) should always point down. Figure 4-6 Surface installation of the SIMATIC RF1000 reader using the table/wall housing 8. Close the table/wall housing. Make sure that the housing sides lock in place.
  • Page 24 Installation SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 25: Connecting

    • For communication via the RS232 interface with any serial module, the connecting cable with open ends (6GT2891-2UH30) Connect the plug The procedure for connecting the reader depends on the interface over which the reader is being operated. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 26 Connecting Connection via USB interface Proceed as follows to connect the SIMATIC RF1000 reader via the USB interface: 1. Connect the reader to the PC or Panel using the USB cable. Connection via RS232 interface Proceed as follows to connect the SIMATIC RF1040R/RF1070R reader via the RS232 interface: 1.
  • Page 27 Connecting ① ③ Brown ② ④ Black Orange Figure 5-2 Connection diagram: Connecting the reader to a serial communications module SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 28 Connecting SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 29: Commissioning

    Reaction: The message "An RF10x0R is being set up." appears. 2. Copy the "RF1000R_Vxxx.exe" file to your PC. You can find the file on the Internet on the pages of the Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/view/109741590). 3. Extract the file.
  • Page 30 = false") or transferring a VHL configuration switches off "Autoread" mode. In this case, the configuration card can only be read in again using the demo application and the "vhl_select()" function (with "AllowConfig = true") or after the reader is reset to factory settings ("syscmd_reset"). SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 31 To do this, please contact Service & Support (Page 93). You will find more detailed information on the configuration card in the configuration manual "SIMATIC RF1000 (https://support.industry.siemens.com/cs/ww/en/ps/24223/man)". VHL functions VHL stands for "Very High Level". VHL functions have a higher priority and are valid for all card systems supported by the reader.
  • Page 32 Commissioning SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 33: Programming

    USB or the RS232 interface. Typical applications Below you will find typical applications for using the SIMATIC RF1000 readers. The applications are shown as an example using the DLL functions. These can be implemented in the same way with the commands.
  • Page 34: Programming Via Usb/Rs232 Interface (Using Dll Functions)

    7.2.1 Functions of the USB/RS232 interface for Windows You can program the reader using access functions. You can find the "RF1000R.zip" file on the Siemens support page "Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/view/109741590)". It includes the DLL files ("BrpDriver_x64" and "BrpDriver_x86"), the DLL functions as well as a demo application which demonstrates the use of the DLL functions.
  • Page 35: Brp_Open_Serial_Session

    The function opens a connection to the reader via the RS232 interface and returns a session key that is required for all functions and continued communication via this connection. If the connection was successfully established, the value "BRP_OK" is returned. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 36 Note that you can operate several RF1040R/RF1070R readers in parallel via the RS232 interface or with the help of a COM port emulator. Function call brp_open_serial_session( int * Handle, int com_port, ser_baudrate baudrate, ser_parity parity SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 37 • 0x01: ser_par_odd • 0x02: ser_par_even Return value • BRP_OK • BRP_ERR_BUSY • BRP_ERR_GENERAL_IO • BRP_ERR_BUFFER_OVERFLOW • BRP_ERR_NO_MORE_HANDLES • BRP_ERR_INSUFFICIENT_MEM You will find more information on return values in the section "Return values (Page 52)". SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 38: Brp_Set_Checksum

    Note that the buffer size is automatically set to the default value of 128 bytes after the restart. Function call brp_set_bufsize( int Handle, int TotalBufsize, int SendBufsize, int RecvBufsize SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 39: Brp_Close_Session

    This function call terminates a connection.   Handle The session key returned by the "brp_open_usb_session" or "brp_open_seri‐ al_session" function. Return value • BRP_OK • BRP_ERR_WRONG_HANDLE You will find more information on return values in the section "Return values (Page 52)". SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 40: Syscmd_Reset

    The function reads out information about the firmware of the reader. The value read out contains information on the type of firmware, the version and the serial number of the reader. Function call syscmd_get_info( int Handle, char * fws, int * Status SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 41: Syscmd_Get_Boot_Status

    Check the value of "boot_status" for the value "0" and output an error or a warning if the values do not match. Function call int syscmd_get_boot_status( int Handle, dword * boot_status, int * Status SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 42: Syscmd_Set_Port

    Note that the LED function is pre-assigned at the factory. The readiness for operation of the readers is indicated by a green LED and the presence of a transponder by a yellow LED. Function call syscmd_set_port( int Handle, word port_mask, int * Status SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 43: Vhl_Select

    "Reselect = false". Then call the "vhl_select" function until all cards in the antenna field are recognized. If no new card is detected, "CARD_NOT_SELECTED_ERR" is returned. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 44 Table 7-12 Assigning the card types CardTypeMask CardType Protocols/card types 0x0001 (bit 1) 0x1X ISO 14443 A / MIFARE 0x0002 (bit 2) 0x2X LEGIC Legacy (only for RF1070R) 0x0004 (bit 3) 0x3X ISO 15693 SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 45: Vhl_Get_Snr

    Note that the least significant byte of the serial number is output first. For RF200/RF300 readers, the most significant byte is usually output first. Function call vhl_get_snr( int Handle, byte * Snr, byte * Length, int * Status SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 46: Vhl_Is_Selected

    You can find more detailed information on the reader status in the section "Status codes (Page 66)". Return value • BRP_OK You will find more information on return values in the section "Return values (Page 52)". SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 47: Vhl_Read

    You can find more detailed information on the reader status in the section "Status codes (Page 66)". Return value • BRP_OK You will find more information on return values in the section "Return values (Page 52)". SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 48: Vhl_Write

    You can find more detailed information on the reader status in the section "Status codes (Page 66)". Return value • BRP_OK You will find more information on return values in the section "Return values (Page 52)". SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 49: Autoread_Setmode (Called Via "Exec_Command")

    "Autoread_GetMessage" function when no card is located in the antenna field. Function call brp_exec_command( int Handle, byte devcode, byte cmdcode, byte * param, byte param_len, init timeout, init * Status, byte * resp, int * resp_len, init max_resp_len SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 50: Autoread_Getmessage (Called Via "Exec_Command")

    Function call brp_exec_command( int Handle, byte devcode, byte cmdcode, byte * param, byte param_len, init timeout, init * Status, byte * resp, int * resp_len, init max_resp_len SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 51: Getlicenses (Called Via "Exec_Command")

    This function reads out which licenses are available on the reader. Function call brp_exec_command( int Handle, byte devcode, byte cmdcode, byte * param, byte param_len, init timeout, init * Status, byte * resp, int * resp_len, init max_resp_len SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 52: Return Values

    The response time has been exceeded. 0x05 BRP_ERR_CORRUPTED_FRAME A bad frame was detected. 0x06 BRP_ERR_UNEXPECTED_FRAME An unexpected frame was detected. 0x07 BRP_ERR_GENERAL_IO The underlying serial port has caused an error. 0x08 BRP_ERR_BUFFER_OVERFLOW The reader sent more data than expected. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 53: Functions Of The Usb Interface For Linux

    Functions of the USB interface for Linux The programming in Linux is made via an API and Software Development Kit. For additional information, contact the Siemens Industry Online Support (Page 93). Alternatively, you can program the USB interface in Linux based on the serial telegrams.
  • Page 54: Implementation Of The Commands

    Application example The following link shows an application example for connecting the RF1040R/RF1070R readers via an RF170C communication module. Application example (https://support.industry.siemens.com/cs/ww/en/view/109770535) 7.3.1 Implementation of the commands The different jobs are described in more detail below. Note that you must wait for the respective response telegram (reader response time) before you can send new request telegrams.
  • Page 55: Commands

    Table 7-23 Response telegram without errors Byte Value Description 0x0C Without checksum 0x1C With checksum 0x00 DevCode of the command set containing the command to be called. 0x03 CmdCode of the command to be called. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 56: Syscmd_Get_Info

    Max. reader response time: 50 ms Table 7-26 Request telegram Byte Value Description 0x0C Without checksum 0x1C With checksum 0x00 DevCode of the command set containing the command to be called. 0x05 CmdCode of the command to be called. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 57: Syscmd_Set_Port

    • 0x06: Acoustic signal (only for RF1040R/RF1070R) and LED lit red • 0x07: Acoustic signal (only for RF1040R/RF1070R) and LED lit orange 0xXX Optional checksum (when the value "0x1C" is set in byte 0) SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 58: Syscmd_Get_Licenses

    0x1C With checksum 0x00 DevCode of the command set containing the command to be called. 0x29 CmdCode of the command to be called. 0x04 Parameter length (e.g. 4 bytes) 0x00 0x00 Reserved 0x00 0x00 SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 59: Vhl_Select

    Parameter length (1 byte) 0x00 0x30 Card type (e.g. 0x30) You can find detailed information on the card types in the section "vhl_select (Page 43)". 0x0D Optional checksum (when the value "0x1C" is set in byte 0) SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 60: Vhl_Get_Snr

    0x1C With checksum 0x01 DevCode of the command set containing the command to be called. 0x01 CmdCode of the command to be called. 0x04 Parameter length, depending on card type (e.g. 4 bytes) 0x00 SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 61: Vhl_Is_Selected

    DevCode of the command set containing the command to be called. 0x04 CmdCode of the command to be called. 3 ... 4 0x00 Parameter length (0 bytes) 0x08 Optional checksum (when the value "0x1C" is set in byte 0) SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 62: Vhl_Read

    CmdCode of the command to be called. 0x08 Parameter length (e.g. 8 bytes) 0x00 5 ... 12 0xCC Read data (e.g. 0xCC) 0xXX Optional checksum (when the value "0x1C" is set in byte 0) SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 63: Vhl_Write

    ID of the VHL function (e.g. 0xFF [factory setting for ISO 15693]) 0x00 Address (e.g. 0x42) 0x42 0x00 Length (e.g. 0x08) 0x08 10 ... 17 0x33 Data to be written (e.g. 0x33) 0xXX Optional checksum (when the value "0x1C" is set in byte 0) SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 64: Autoread_Setmode

    Value Description 0x0C Without checksum 0x1C With checksum 0x05 DevCode of the command set containing the command to be called. 0x00 CmdCode of the command to be called. 0x01 Parameter length (1 byte) 0x00 SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 65: Autoread_Getmessage

    0x05 DevCode of the command set containing the command to be called. 0x01 CmdCode of the command to be called. 0x07 Parameter length (7 bytes) 0x00 0x00 Message type 0x05 Message length (e.g. 0x05) SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 66: Status Codes

    TIMEOUT_ERR The reader is currently in timeout. 0x82 FRAME_ERR Invalid command from host. 0x83 AME_OVERFLOW_ERR The length of the response exceeds the maximum permis‐ sible length. 0x84 CHK_ERR Invalid checksum in the host command. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 67 The functions are constructed so that if execution fails, they are automatically repeated. This compensates any communications problems that may occur, e.g. due to bad RF signal quality as a result of external influences. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 68 Programming 7.4 Status codes SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 69: Demo Application

    Demo application The demo application contained in the file "RF1000R_Vxxx.exe" helps you to understand the available functions. You will find the file on the Siemens "Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/view/109741590)". The available software package contains a demo application based on "Windows .NET 3.5"...
  • Page 70 Demo application 8.1 User interface of the demo application Working with the demo application Follow the steps below to work with the demo application: 1. Start the demo application by double-clicking on the file "AccessControlDemo.exe". SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 71 Selection of the COM port used   Read SerNr Read the serial number and the card type.   Read Data (auto) Automatic reading of the transponder data depending on the specific card type configuration. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 72: Creating A Custom Application

    5. Click the "Stop" button to disconnect the reader. Creating a custom application You can create custom applications for operation via USB or RS232 interface. The creation of some sample applications is described below. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 73 – The application signals that the transponder with the serial number "x" is no longer recognized. 3. Terminate the connection to the reader ("brp_close_session"). The source code of the demo application can serve as an example for your own application. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 74 – The transponder is recognized automatically. – Read out the transponder data ("Autoread_GetMessage" / "exec_command", devcode = 0x05, cmdcode = 0x01) The source code of the demo application can serve as an example for your own application. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 75 – You can write data to the memory area with the "vhl_write" function. 3. Terminate the connection to the reader ("brp_close_session"). The source code of the demo application can serve as an example for your own application. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 76 "vhl_select = STATUS_OK" is returned. 3. Terminate the connection to the reader ("brp_close_session"). 4. Establish the connection to the reader again ("brp_open_usb_session"). The source code of the demo application can serve as an example for your own application. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 77 Demo application 8.2 Creating a custom application Figure 8-5 "Transfer reader configuration" flow diagram SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 78 Demo application 8.2 Creating a custom application SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 79: Technical Specifications

    Technical specifications Technical specifications of SIMATIC RF1000 Table 9-1 Technical specifications of the SIMATIC RF1000 reader     6GT2831-6xAx0 6GT2831-6BAx0-0AX0 Product type designation SIMATIC RF1040R SIMATIC RF1060R SIMATIC RF1070R   Radio frequency Operating frequency     • RFID • RF1040R: 125 kHz; 13.56 MHz •...
  • Page 80 Technical specifications 9.1 Technical specifications of SIMATIC RF1000     6GT2831-6xAx0 6GT2831-6BAx0-0AX0   Interfaces Interface to the communications module • USB 2.0, Type A (480 Mbps) • RS232 (115.2 kBd; no parity) RFID Integrated antenna Integrated antenna (default: deactivated)   Supply voltage, current consumption, power loss Power supply 4.6 to 5.25 V DC...
  • Page 81: Technical Specifications, Rf1100T Configuration Card

    Data retention time (at < 40 ℃) > 10 years Write/read distance (S ≤ 30 mm   Mechanical specifications Housing     • Material •   • Color • White Printing Writeable handwritten   Permitted ambient conditions SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 82: Technical Specifications Of The License Cards

    Technical specifications of the license cards Table 9-3 Technical specifications of the license cards     6GT2300-0CC00-0AXx Product type designation HID license card for SIMATIC RF1000 and RF1100 BLE license card for SIMATIC RF1000   Mechanical specifications Housing   •...
  • Page 83: Technical Specifications Of Table/Wall Housing

    Technical specifications 9.5 Technical specifications of cleanroom cover Technical specifications of table/wall housing Table 9-4 Technical specifications of table/wall housing for SIMATIC RF1000     6GT2890-0CB00 Product type designation Table/wall housing RF1000   Mechanical specifications Housing     • Material •...
  • Page 84 Technical specifications 9.5 Technical specifications of cleanroom cover SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 85: Dimension Drawings

    Dimension drawings All dimensions in mm ① Figure 10-1 Dimension drawing SIMATIC RF1000 with optional card holder Figure 10-2 Dimension drawing of the table/wall housing SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 86 Dimension drawings Figure 10-3 Dimension drawing of SIMATIC RF1000 with the cleanroom cover "Cabinet installation" Figure 10-4 Dimension drawing of SIMATIC RF1000 with the cleanroom cover "Surface installation" SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 87: Appendix

    "This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: • (1) This device may not cause harmful interference, and • (2) this device must accept any interference received, including inter‐ ference that may cause undesired operation." SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 88 • 2) l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Importer UK: Siemens plc, Sir William Siemens House, Princess Road, Manchester M20 Brazil (ANATEL) Certificado de Homologação REPÚBLICA FEDERATIVA DO BRASIL AGÊNCIA NACIONAL DE TELECOMUNICAÇÕES...
  • Page 89: Connection Via Remote Desktop Protocol (Rdp)

    To do this, enter "cmd" in the Windows search field. 7. In the command prompt, enter "gpupdate /force" to update the group policies. 8. Restart the client computer for your changes to take effect. SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 90: Ordering Data

    Ordering data Table A-2 Ordering data Product Article number SIMATIC RF1040R (AS: E) 6GT2831-6CA50 SIMATIC RF1060R (AS: E) 6GT2831-6AA50 SIMATIC RF1070R (AS: H) 6GT2831-6BA50 SIMATIC RF1070R (AS: H) 6GT2831-6BA50-0AX0 OEM variant with neutral front foil SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 91 6GT2890-0CD00 Cleanroom cover surface installation for RF1000 6GT2890-0CC00 Configuration card RF1100T 6GT2300-0CC00-0AX0 (pack of 5) HID license card for SIMATIC RF1000 and RF1100 6GT2300-0CC00-0AX1 BLE license card for SIMATIC RF1000 6GT2300-0CC00-0AX2 Power supply unit LOGO! Power 6EP3310-6SB00-0AY0 5 V / 3 A Optional USB connecting cable 0.5 m...
  • Page 92 Appendix A.3 Ordering data SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...
  • Page 93: Service & Support

    Industry Online Support In addition to the product documentation, you are supported by the comprehensive online information platform of Siemens Industry Online Support at the following Internet address: Link: (https://support.industry.siemens.com/cs/de/en/) Apart from news, you will also find the following there: •...
  • Page 94 Service & Support SIMATIC RF1000 Operating Instructions, 05/2023, C79000-G8976-C432-10...

Table of Contents