Siemens SIMATIC RF166C Operating Instructions Manual

Siemens SIMATIC RF166C Operating Instructions Manual

Hide thumbs Also See for SIMATIC RF166C:
Table of Contents

Advertisement

Quick Links

SIMATIC RF166C
SIMATIC Ident
RFID systems
SIMATIC RF166C
Operating Instructions
03/2022
C79000-G8976-C578-02
Introduction
Security recommendations
Description
Mounting
Connecting
Configuring
Configuration using the
WBM
Programming
Service and maintenance
Technical specifications
Dimensional drawings
Appendix
Syslog messages
Service & Support
1
2
3
4
5
6
7
8
9
10
11
A
B
C

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC RF166C

  • Page 1 SIMATIC RF166C Introduction Security recommendations SIMATIC Ident Description Mounting RFID systems SIMATIC RF166C Connecting Configuring Operating Instructions Configuration using the Programming Service and maintenance Technical specifications Dimensional drawings Appendix Syslog messages Service & Support 03/2022 C79000-G8976-C578-02...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Assigning the IP address with SINEC PNI ................49 Configuration via PROFIBUS (STEP 7) .................. 50 Configuration via XML ....................... 56 Configuration via OPC UA....................56 Configuration using the WBM ......................57 Starting WBM ........................57 The WBM ........................... 60 SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 4 Reset the factory setting with SINEC PNI ................132 9.4.3 Restoring the factory settings for the hardware ..............133 Module replacement ......................134 9.5.1 Backup configuration data ....................135 9.5.2 Replacing a module ......................136 SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 5 Ordering data ........................152 Certificates & approvals....................154 Syslog messages ..........................157 Structure of the Syslog messages ..................157 Variables in Syslog messages ................... 158 List of Syslog messages ....................159 Service & Support ..........................163 SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 6 Table of contents SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 7: Introduction

    (RF200, RF300, RF600, MV400 and MV500). Further information on the PROFIBUS can be found in the "PROFIBUS Network Manual". You can find the current versions of the various manuals on the pages of the Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/14970/man).
  • Page 8 Do not dispose of the products at public disposal sites. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste or your Siemens representative. Adhere to the various country-specific regulations.
  • Page 9: Security Recommendations

    • The devices have "Low-level service access" that can only be enabled via additional hardware interconnection. The access is used to enable Siemens personnel to perform advanced examination for servicing. The access may only be used by qualified service personnel.
  • Page 10 • We recommend that you use certificates with a key length of at least 4096 bits. • If protocols support both certificates and keys, you should favor certificates. • With operation via OPC UA, always use the "Sign and encrypt" security method. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 11 Make use of the possibility to prevent write access. The product offers corresponding settings for this. • If SNMP is activated, change the community names. If no unrestricted access is necessary, restrict access over SNMP. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 12 • When using OPC UA, only use profiles with secure encryption and authentication. List of available protocols All available protocols and their ports that are used with SIMATIC RF166C are listed below. Table 2- 1 List of available protocols...
  • Page 13: Security Information

    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to...
  • Page 14 Security recommendations 2.1 Security information SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 15: Description

    Properties of the communications modules Area of application The SIMATIC RF166C communications modules are designed for use in all areas of automation within an access-protected area. It covers all areas in which SIMATIC Ident RFID readers and optical readers are operated. The application takes place in the field level over PROFIBUS via a controller.
  • Page 16: User-Specific Procedure

    OPC UA environment, the extended configuration and programming is performed from the perspective of an OPC UA user. If you want to adapt the communication modules to your requirements, we recommend the following user-specific procedure: SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 17 You will find information on this in the section "Configuration via OPC UA (Page 56)" or "Configuration using the WBM (Page 57)". 4. Reading diagnostic information You can find information on this in the section "Programming via OPC UA (Page 103)". SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 18: Design

    ⑧ 2x interface for PROFIBUS (M12, 5-pin, B-coded) ④ Ethernet interface ⑨ PROFIBUS address adjuster (M12, 4-pin, D-coded) ⑤ Ethernet LED ⑩ Mounting holes and functional ground Figure 3-2 Design of the communication module SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 19 The GSD file is stored on the communication module and can be downloaded from it using a Web browser. You can also find the GSD file at the website of Siemens Industry Online Support. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 20 Description 3.3 Design SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 21: Mounting

    Mounting rules Note Mounting the communication modules Only install the communication module when supply voltages are switched off. You do not have to observe any special rules when installing the communication modules. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 22: Mounting The Communications Module

    1207 / DIN EN ISO 1580 If you need washers, use washers conforming to DIN EN ISO 7089 / DIN EN ISO 7090. Cylinder head screw with M4 hex socket according to DIN EN ISO 4762 SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 23 Fasten the communication module with the screws on a solid level surface. The device must be screwed (≤ 1.2 Nm) onto the panel at both fastening points (front top and bottom). ① Elongated hole: 4.5 mm width × 5.0 mm height Figure 4-1 Installing RF166C communication module SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 24 The following figure shows the upper left fastening point for 2.5 mm wide cable ties. Figure 4-2 Securing RF166C communication module with cable ties SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 25: Use At Altitudes Over 2,000 M

    Information on the nameplate You will find the currently valid markings and approvals on the nameplate of the communication module. All other markings and approvals are currently based on an altitude up to 2,000 m. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 26 Mounting 4.3 Use at altitudes over 2,000 m SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 27: Connecting

    RF166C, it is possible that the connected device may be destroyed. PROFIBUS connection system You can find detailed information on PROFIBUS DP in the "PROFIBUS Network Manual (https://support.industry.siemens.com/cs/ww/en/view/35222591)" system manual. CAUTION Power supply All supply and signal voltages must be safety extra low voltage (SELV/PELV according to IEC 61140).
  • Page 28: Network Topology

    Configuration graphic of a line/series topology With a line/series topology, remember that if the communication connection of a communications module to the controller is interrupted, the communication connection to all downstream communications modules is also interrupted. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 29: Operation Of The Cm On Grounded/Ungrounded Power Supply

    Configuring RF166C with ungrounded reference potential When the communications module is set up with ungrounded reference potential, any interference currents occurring are conducted to functional ground via an internal RC network (no external connection between 1M and FE). SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 30 Fuses for line protection (automatic circuit breaker for 16 A) ④ When setting up the communications module with ungrounded reference potential, there is no connection between 1M, 2M and FE Figure 5-3 Electrical design SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 31 Insulation monitoring Isolation monitoring must be provided in the following cases: • Design of the communications module with ungrounded reference potential • If hazardous plant states can be expected as a result of faults. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 32: Electrical Design Of The Cm

    • Load voltage 2L+ and all other circuit components • Communication interfaces (PROFIBUS) of the communication module and all other circuit components The following figure shows the potential relationships of the communication modules. Figure 5-4 Potential relationships of the communication modules SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 33 Load voltage (2L+) has no direct effect on the RF166C communication module. The following figure shows a configuration with another voltage supply for the communications modules. The different potential groups are highlighted in gray. Figure 5-5 Wiring of the power supply SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 34: Connecting Cm To Functional Ground

    Required tools You need the following tool to connect to the functional ground: • Screwdriver Accessories required You need the following accessories to connect to the functional ground: • Fastening screw (M4) and washer SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 35 Ensure there is a low-impedance connection between the communications module and the conductive base and between the conductive base and functional ground. ① Grounded, metallic base ② Unpainted thread or nut support Figure 5-6 Mounting the CM on a conductive base SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 36: Mounting The Cm On A Non-Conductive Base

    To connect to functional ground with a non-conductive mounting base, you can need the following accessories: • Fastening screw (M4) and washer • Cable lug suitable for M4 screws • Ground conductor cable (copper braid) with a minimum cross-section of 4 mm SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 37 1.2 Nm. NOTICE Grounding with non-conductive mounting base Ensure a low impedance connection between the communications module and functional ground. Figure 5-7 Mounting the CM on a non-conductive base / connection to functional ground SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 38: Connecting The Communications Module

    You can loop the supply voltages and PROFIBUS via the M12 round sockets ⑦ + ⑧. The pin assignments of the various interfaces are lasered on the side of each communication module at the factory. Requirement Only wire the communication module when the supply voltage is switched off. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 39 M12 plug (4-pin, L-coded) and 4-wire cable (4 x 1.5 mm • For the PROFIBUS connection M12 plug (5-pin, B-coded) and 2-wire PROFIBUS cable (shielded) You can find the associated article numbers in the section "Ordering data (Page 152)". SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 40 Functional ground / shielding / shielding Table 5- 3 Pin assignment Ethernet; M12 socket (4-pin, D-coded) Assignment View of M12 socket, 4-pin Data line TxP Data line RxP Data line TxN Data line RxN SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 41 Data reference potential M5 Data line B Functional earth (FE): The voltage may be used exclusively to supply the external terminating resistor. Looping the voltage through to the next connector via a cable is not permitted. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 42 Connector for the reader connection (M12, 8-pin, A-coded) ② Connector for the Ethernet connection (M12, 4-pin, D-coded) ③ Connector for the power supply (M12, 4-pin, L-coded) ④ Connector for PROFIBUS connection (M12, 5-pin, B-coded) Figure 5-9 Connect the plug SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 43: Loop-Through Of The Supply Voltage And Profibus

    1.5 mm². If you do not observe the maximum permissible supply current and the cable cross- section required, this may result in the cable isolation and contacts overheating and in the device being damaged. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 44: Effect Of Cable Length On The Supply Voltage

    0.2 V. The value can vary significantly depending on the plug connection or condition. When using a 7 m power cable with ∅ 1.5 mm , the voltage drop is approx. 2.6 V with a 16 A load. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 45: Setting The Profibus Dp Address

    – Upper rotary encoder switch: 10th position – Lower rotary encoder switch: 1st position 3. Screw the two M12 seal caps back onto the threads to protect the rotary coding switches (torque: 0.5 to 0.8 Nm). SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 46 PROFIBUS address adjuster on the RF166C The following table below shows the setting for PROFIBUS address "26" as an example: Table 5- 6 Setting example of the PROFIBUS address 10th position Position 2 1st position Position 6 SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 47 It can be screwed onto the unused PROFIBUS interface of the CM. The following figure shows a typical application for a terminating resistor. ① PROFIBUS connection ② Terminating resistor Figure 5-13 Terminating resistor on RF166C SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 48 Connecting 5.8 Setting the PROFIBUS DP address SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 49: Configuring

    OPC UA, it may be necessary to change the IP address. Requirements SINEC PNI is installed and the communications module is connected and running. You can find the SINEC PNI on the pages of the "Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/26672/dl)". Procedure...
  • Page 50: Configuration Via Profibus (Step 7)

    WBM ("The "System - Device settings" menu item (Page 100)"). You can also find the GSD file at the website of Siemens Industry Online Support. If the communication modules are integrated into an automation system using the GSD file, some of the following parameters may not be displayed.
  • Page 51 You can set the basic parameters of the communication module, as well as the parameters of the readers connected to the communication module, using the properties window of the communication module. You can set all module-specific parameters using the following parameter groups. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 52 Generation, as of FW 1.8) • RF600: Submodule for connecting the SIMATIC RF600 readers • Empty: If no device is connected to interface X21, you need to assign an "Empty" submodule to this interface. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 53 No alarms are generated. • Hard errors: Critical hardware errors/faults are reported by the S7 diagnostics. • Hard/soft errors: Critical hardware faults and errors occurring when processing commands are reported by the S7 diagnostics. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 54 The stop bits are appended to every transferred character during transmission. Interface RS422 RS422 Selection of the interface type that the connected hardware (reader / optical readers) RS232 uses. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 55 Entry of the second end delimiter of a maximum of two end delimiters for the end criteria "On receipt of the end delimiter(s)". The selected end delimiter combination limits the length of the frame. Parameter value depending on the "Data bits" parameter. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 56: Configuration Via Xml

    Configuration of the communications module is not possible for pure OPC UA work. However, you can read diagnostic data from the communications modules via OPC UA. You will find detailed information on this in the manual "OPC UA for SIMATIC Ident (https://support.industry.siemens.com/cs/ww/en/ps/14971/man)". SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 57: Configuration Using The Wbm

    IP address. To achieve a good workflow with the WBM, we recommend that you use a PC that meets the following minimum requirements: • CPU: DualCore • RAM: 2 GB SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 58 Both IP addresses must be located in the same subnet. • Make sure that the connection is not blocked by a firewall. • Use a ping request to check the connection between the PC and the communication module. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 59 Depending on whether the authentication is enabled or disabled, you may have to log in with your user name and the corresponding password. The WBM homepage opens after logging in, even if authentication is disabled. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 60: The Wbm

    7.2 The WBM The WBM You can use the WBM to configure the SIMATIC RF166C communications modules. After you have created new user profiles, you need to log in with one of these user profiles when you restart the WBM.
  • Page 61 Remember that this data is only loaded in the WBM. To transfer the data to the communication module, you also need to click the "Transfer configuration to communication module" button. Key combination: Ctrl + O SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 62 WBM. To make sure that this change is not lost, you should load the configuration from the communications module. • This symbol indicates that it is a change that leads to a restart of the communications module when it is transferred. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 63 You will find a list of the restrictions in the section "The "User management" menu item (Page 94)". Main window ③ The main window shows the contents of the selected menu items. Here, you can configure the various menu-dependent parameters. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 64: The Menu Items Of The Wbm

    The "Start page" menu item The "Start page" menu item is divided into the following areas: • Device-specific information • Project ID • Address information (PROFIBUS) • Address information (Ethernet) • Device clock • Configuration display SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 65 The third area contains the configured PROFIBUS address of the communication module as well as the configured transmission speed. Note that a change of the PROFIBUS address only takes effect and thus also displayed as soon as the communication module has been restarted. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 66: The "Settings - General" Menu Item

    7.3.2 The "Settings - General" menu item The "Settings - General" menu item is divided into the following area: • Log settings • Service logbook settings Figure 7-4 The "Settings - General" menu item SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 67 Frames on reader interface 2 (X22) Detailed information Line Recording of the line monitoring frames (CMD_XML and CMD_PLC) for service monitoring information. Can be switched off to keep the logbook free for payload data. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 68: The "Settings - Reader Interface" Menu Item

    The settings of each interface are identically structured and divided into the following areas: • Basic settings • Reader parameters Figure 7-5 The "Settings - Reader Interface" menu item SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 69 In the text box, you can assign a name to the read point(s) (for example, "Incoming goods gate 5" or "Welding robot 21"). Note that the name is required for addressing the reader via OPC UA. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 70 Using the "Update firmware" link, you jump to the "System - Reader firmware" menu item in which you can update firmware for the connected reader. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 71 LED in the event of an error is reset by a "init_run" or "WRITE-CONFIG" with "Init" (RESET) or after the successful execution of a command. Max. number of 1 ... 40 Number of transponders expected in the transponders antenna field. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 72 The selectable values depend on the value specified in the parameter "Ident device / system". • RF290R – Range of values: 0.50 ... 5.00 W – Default value: 1.00 W • RF380R – Range of values: 0.50 ... 2.00 W – Default value: 1.25 W SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 73 MOBY E RF300, MOBY E ISO 15693 None ISO 15693 General MDS D1xx, NXP MDS D2xx, TI MDS D261, STM MDS D3xx, Infineon MDS D4xx, Fujitsu - 2 KB MDS D5xx, Fujitsu - 8 KB SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 74 Selection of the number of bits to which a character is mapped. Stop bits Selection of the number of stop bits that indicate the end of a character. The stop bits are appended to every transferred character during transmission. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 75 Depending on the data transmission speed, the character delay time is limited to a minimum value. Note that the ASCII driver also pauses between two frames during transmission. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 76: The "Settings - Communication" Menu Item

    The "Network interfaces" tab The "Network interfaces" tab is divided into the following areas: • Network basic settings • SNMP • NTP • Syslog messages Figure 7-6 The "Settings -- Communication" menu item, "Network interfaces" tab SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 77 In this box, changes can only be made if write access was permitted. Write access is only possible for the SNMP variables "sysName", "sysLocation" and "sysContact" of the "system" group of MIB-II. Allow write Check box to enable/disable write protection for SNMP variables. access SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 78 Text box for entering the address of the Syslog server to which the Syslog server Syslog messages are transferred. Default port Text box for entering the default port of the Syslog server via which the Syslog messages are transferred. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 79 7.3 The menu items of the WBM The "XML" tab The "XML" tab is divided into the following areas: • XML basic settings • Diagnostic events of XML channel (1-2) Figure 7-7 The "Settings - Communication" menu item, "XML" tab SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 80 User-defined: No default setting. XML communication can be set as desired. XML channel (1-2) Using the input boxes, you can enable/disable the respective XML channels and define the Ethernet ports of the respective XML channels. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 81 The "OPC UA" tab is divided into the following areas: • OPC UA basic settings • Diagnostic events and items • Security settings Figure 7-8 The "Settings - Communication" menu item, "OPC UA" tab SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 82 OPC UA variables of the "Diagnostics" group. Logbook events If the check box is selected, all logbook entries are sent. Transmitting interface (logbook events) Interface (1-4) Selection of the interface via which the selected entries are transmitted. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 83 • If the partner certificate was issued by several CAs (Certification Authorities), all CA root certificates must be stored in the certificate store of the reader. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 84: The Menu Command "Diagnostics - Hardware Diagnostics

    In "Diagnostics - Hardware diagnostics", you can display the status parameters of the selected reader and of the transponder currently in the antenna field. This page is divided into the following areas: • Basic settings • Monitoring status • Status • Error counter SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 85 Hardware type of the reader Hardware version Hardware version of the reader Bootloader version Bootloader version of the reader Firmware version Firmware version of the reader Driver type Driver type of the serial interface of the reader SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 86 P2P master & combined mode with ISO transponder (MDS Dxxx) 0x50 P2P master & combined mode with RF300 transponder 0x4F P2P slave Antenna status Status of the antenna Presence check Set presence check profile SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 87 AMLI AM power indicator Received signal strength [dB] for which amplitude modulation with the transponder was detected. PMLI PM power indicator Received signal strength [dB] for which phase modulation with the transponder was detected. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 88: The "Diagnostics - Log" Menu Item

    The menu item "Log" shows all message types that were selected in the menu item "Settings - General" in the "Log settings" area. This menu item documents the actions performed by the communications module. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 89 With the "ISO 8601 (UTC)" check box, you can convert the data display in the "Date/Time" column to UTC time, identical to the output in the exported logbook. With a large number of log entries in the history, it may take several minutes before these are displayed. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 90: The "Diagnostics - Service Log" Menu Item

    The log records internal processes of the communication module and is required for service support by SIEMENS specialists. Only make settings on this page if you are instructed to do so by SIEMENS personnel. The log entries are also evaluated by SIEMENS personnel.
  • Page 91 • Service file All data of the communications module relevant for diagnostics are stored as a *.slf file. The file only contains information relevant for Siemens service personnel and can only be evaluated by them. With the "ISO 8601 (UTC)" check box, you can convert the data display in the "Date/Time"...
  • Page 92: The "Diagnostics - Syslog Logbook" Menu Item

    The displayed log entries contain 128 KB of data. 7.3.9 The "Edit transponder" menu item You can read out and write transponder data with the "Edit transponder" menu item. This page is divided into the following areas: • Basic settings • Read/write SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 93 With the "Read" button, the data is read from the transponder. The data read from the transponder is highlighted in red to distinguish it from the data entered manually. If no values are displayed, this means that no values have yet been read from the transponder. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 94: The "User Management" Menu Item

    The "User profiles" area contains a list of all existing user profiles. Up to a maximum of 30 user profiles can be created. To edit a user profile, select the required user name in the list. The selected user name is highlighted in color. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 95 OPC UA connection. This role has no rights whatsoever in the WBM and it cannot be used to log on to the WBM. Click the "Save" button to save the changes and to create the new user profile. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 96 To ensure that no unauthorized persons can access the communications module settings, we recommend that you enable the authentication and create new user profiles. Note that authentication can only be enabled/disabled by an administrator. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 97: The "Homepage" Menu Item

    Certificates always consist of a certificate file and a certificate key file that you must transfer to the communications module. Remember that you first need to import the data into the communications module before you can activate it. Contact your administrative IT department for more information on the topic. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 98 To do so, select the desired certificate in the list and click on the "Delete" button. Certificate details List with detail information on the selected certificate Detailed information about the certificate details is available in the X.509 specifications. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 99 Click the "Create CSR" button to create a certificate signing request (CSR). The CSR file contains all relevant information of the installed server certificate. A CA (Certificate Authority) can create a signed, module-specific server certificate using this file that you can then import into this module. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 100: The "System - Device Settings" Menu Item

    • Check You can use the "Check" button to check the integrity of the firmware. You can use this function to check whether the firmware matches the firmware published by Siemens or whether it has possibly been maliciously modified. Factory setting In the "Factory setting"...
  • Page 101: The Menu Command "System - Reader Firmware

    In this area, you can use the "Reader interfaces" parameter to specify the reader for which a firmware update is to be performed. Depending on the connected reader, you can select the desired read point. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 102: The "Help" Menu Item

    Manual With the "Help - Manual" menu item, you can find the manual for the corresponding communications modules "SIMATIC RF166C". Readme OSS In the "Help - Readme OSS" menu item, you will find the Readme OSS file with the copyright information for the open source software contained in this firmware.
  • Page 103: Programming

    Programming via SIMATIC controller This section is intended only for S7 users. You can program and configure the SIMATIC RF166C communication modules using Ident instructions via a SIMATIC controller. To configure Ident systems using STEP 7 Basic / Professional (TIA Portal), you need appropriate Ident instructions.
  • Page 104 Programming 8.3 Programming via OPC UA SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 105: Service And Maintenance

    • Via the LED displays of the communication modules • Via SNMP • Using WBM • Via the TIA Portal (STEP 7 Basic / Professional) • Via OPC UA These alternative methods are described below. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 106: Diagnostics Via The Led Display

    Shows whether an Ethernet connection is present. • LINK ④ PROFIBUS LED display Shows whether a PROFIBUS connection via the PROFIBUS • interface is available. Figure 9-1 LED displays of the RF166C communication module SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 107 The reader is configured (reset telegram has been sent). LED test while the CM is starting up. The flash test is performed for reader identification. At the same time, the LEDs of the reader, PROFIBUS and Ethernet LED display also flash. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 108 Display of the Ethernet states via the Ethernet LED display LINK Meaning • No connection is available. • No cable has been connected. • LED test while the CM is starting up. • A connection is available. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 109: Diagnostics Via Snmp

    • SNMPv2.mib • SNMPv2Smi.mib You can find the MIB files corresponding to the communication modules on the pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/view/67637278) (automation MIBs), information on the MIB files under "Network management diagnostics and configuration with SNMP (https://support.industry.siemens.com/cs/ww/en/view/103949062)".
  • Page 110: Diagnostics Using The Wbm

    In the "Log" menu, you can find all the diagnostics messages of the communication module that have occurred. The "Service log" helps SIEMENS specialists to analyze errors. You can read out the syslog messages from the "Syslog log" and you can read out the "Status parameters"...
  • Page 111 – Current diagnostic information of the reader interfaces is displayed under the "Channel diagnostics" entry. Figure 9-2 Display of the diagnostics information of the communication module Reading out diagnostics information of the connected readers Requirement: The diagnostic interrupt messages of the reader have been activated. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 112: Diagnostics Via Xml

    This section is intended only for XML users. Comprehensive diagnostics options are available to you via XML. You can find detailed information on the diagnostic options that can be found in the "XML programming for SIMATIC Ident (https://support.industry.siemens.com/cs/ww/en/view/109781631)" manual. 9.1.6 Diagnostics over OPC UA Comprehensive diagnostics options are available to you via OPC UA.
  • Page 113: Parameterization Of The Diagnostics

    • Hard / soft errors In addition to the hard errors, errors that arise during command processing are also reported in this case. Please note that messages triggered by command processing are automatically taken back after 3 seconds. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 114: Diagnostics Via S7 Controller

    Error message of Ident profile error_code_1 Error message of Ident profile error_code_2 Error message of Ident profile Additional information moby_code_1 moby_code_2 moby_code_3 moby_code_4 Error information of FB 45 ("Error_MOBY") meldecode Error codes for diagnostics alarms SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 115 Antenna 7: Antenna type or version is incorrect 0x40 Antenna 8: Antenna type or version is incorrect 0x4C Alarm buffer overflow 0x4E Low power supply of the RFID reader 0x4D Error in the reader firmware SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 116: Error Messages

    The address range of the transponder has been exceeded. Possible causes: • Start address of the command start has been incorrectly set. • Wrong transponder type • The area to be written to is write-protected. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 117 Contact Support if needed. 0xE1FE8500 The transponder has too little power to execute the command. Possible causes: • Transponder is in the limit area. • The transmission/radiated power of the reader or antenna is too low. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 118 Freeport: Negative acknowledgment or bad frame from the reader 0xE2FE0200 • More transponders are located in the transmission window than can be processed at the same time by the reader. • There is more than one transponder in the transmission window. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 119 0xE4FE8100 The specified tag field of the transponder is unknown. 0xE4FE8A00 General error 0xE4FE8B00 No or bad configuration data/parameters were transferred. Possible causes: • You are accessing a read point that is not configured. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 120 Incorrect sequence number order (SN) on the reader/communication module 0xE5FE0200 Incorrect sequence number order (SN) in the Ident profile Possible cause: User mode "Ident profile/RFID standard profile" is not set in the device configuration. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 121 The "AdvancedCmd" block was supplied with an incorrect "CMD". • The "CMD" input of the "AdvancedCmd" block was overwritten. Freeport: Incorrect command parameters or unauthorized command chaining (incorrect length specification) 0xE6FE0200 Invalid command index (CI) SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 122 • After eliminating the error, execute an "INIT". • Check the parameter "IID_HW_CONNECT". 0xE6FE8100 A parameter is missing. 0xE6FE8200 The parameter has an invalid format. 0xE6FE8300 The parameter type is invalid. 0xE6FE8400 Unknown parameter. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 123: Reading Out Error Messages Using The Wbm

    All the diagnostics messages of the communication module are entered in the "Log" if a check mark was set for "ERRORS" in the WBM configuration in "Settings - General". You will find further information on the "Log" in the section "The "Diagnostics - Log" menu item (Page 88)". SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 124: Opc Ua Error Messages

    The address range of the transponder has been exceeded. Possible causes: • Start address of the command start has been incorrectly set. • Wrong transponder type • The area to be written to is write-protected. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 125 The selected frequency is not enabled. ERROR good RF_COMMUNICATION_ The carrier signal is not activated. ERROR good RF_COMMUNICATION_ General radio protocol error ERROR good DEVICE_FAULT Fault in power supply The power supply is very close to the low limit. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 126 BadInvalid A parameter is missing. Argument BadInvalid The parameter has an invalid format. Argument BadInvalid The parameter type is invalid. Argument BadInvalid Unknown parameter. Argument The command or the frame has an invalid format. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 127: Firmware Update

    "RUN" LED is lit/flashes green. Note that the startup process takes approx. 1 minute after a firmware update. The updated firmware is active following the restart. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 128: Update Firmware Via Tia Portal (Step 7 Basic / Professional)

    Alternatively, you can also start an update directly from the TIA Portal in the "Online & Diagnostics" menu via the "Functions > Firmware update" entry. You can find current update files (*.upd) on the pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/26276/dl).
  • Page 129: Updating The Firmware Of The Reader Via Wbm

    Result: The firmware of the reader is updated. The update process is indicated in the information bar. After the update has completed, the reader is restarted. The updated firmware is active following the restart. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 130: Updating Firmware Of The Readers Using The Tia Portal (Step 7 Basic / Professional)

    – Note: If the check box is not selected, the new firmware is only activated on the next startup of the communication module. 10.Click the "Start upgrade" button. Result: The firmware is updated. The update process is displayed. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 131: Factory Settings

    The communications module is ready for operation when the "RUN" LED is lit/flashes green. After restarting the communications module, you may have to assign a new IP address or a new device name to the communications module. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 132: Reset The Factory Setting With Sinec Pni

    The communications module is ready for operation when the "RUN" LED is lit/flashes green. After restarting the communications module, you may have to assign a new IP address or a new device name to the communications module. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 133: Restoring The Factory Settings For The Hardware

    With the factory settings, the IP address is obtained via a DHCP server. After restarting the communications module, you may have to assign a new IP address or a new device name to the communications module. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 134: Module Replacement

    • On the controller • Using the TIA Portal (STEP 7 Basic / Professional) in a STEP 7 project • Using the WBM on your PC These alternative methods are described below. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 135: Backup Configuration Data

    These buttons enable you to save configurations, reload them and transfer them to other communication modules. You will find further information on saving and loading the configuration on or from the PC in the section "The WBM (Page 60)". SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 136: Replacing A Module

    5. Set the PROFIBUS address on the communication module. 6. Connect the communication module to the PC or the SIMATIC controller using the available Ethernet/PROFIBUS cable. 7. If necessary, connect the communications module to one or more readers. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 137 LED is lit/flashing green). 9. If necessary, assign a unique IP address to the communication module. 10.Load the configuration onto the communications module, if applicable. 11.Configure the user management according to the requirements of your application. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 138 Service and maintenance 9.5 Module replacement SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 139: Technical Specifications

    Technical specifications Table 10- 1 Technical specifications for RF166C 6GT2002-0EE20 Product type designation SIMATIC RF166C PROFIBUS interface Connection type PROFIBUS DP-V1 Physical medium RS485 Transmission speed 9.6 Kbps ... 12 Mbps Connector 2x M12 interface, 8-pin, B-coded Maximum block length •...
  • Page 140 Depending on the connected reader. All supply and signal voltages must be safety extra low voltage (SELV/PELV according to IEC 61140) 24 V DC supply: Safety (electrical) isolation of low voltage (SELV/PELV acc. to IEC 61140) SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 141: Dimensional Drawings

    Dimensional drawings ① Elongated hole: 4.5 mm width × 5.0 mm height Figure 11-1 Dimension drawing on an RF166C communication module (all dimensions in [mm]) SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 142 Dimensional drawings SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 143: Appendix

    Appendix System planning The SIMATIC RF166C communication module is only one of many devices in the SIMATIC Ident portfolio. In addition to the communications module, an industrial identification system also consists of a higher-level controller/PC, connecting cables, as well as readers and/or optical readers.
  • Page 144: Connecting Cables

    A reader connector with screw terminals is available for self- assembly (see the relevant system manual). Cables and reader connectors can be ordered using the TIA Selection Tool or the SIMATIC Ident Configuration Guide. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 145 +24 V +24 V White -RxD Brown Green +RxD Yellow +TxD +5 V Gray -TxD Pink Functional Functional Metal mesh ground / ground / shielding shielding The wire color relates to the connecting cable "6GT2891-4Fxxx". SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 146: Operation Of Optical Handheld Readers, Access Control Readers Or Serial Devices

    The manuals of the relevant devices contain information on the parameterization options for the devices stated in the following: • SIMATIC MV320 (https://support.industry.siemens.com/cs/ww/en/ps/15157/man) • SIMATIC RF1000 (https://support.industry.siemens.com/cs/ww/en/ps/24223/man) You will find the parameter assignment options of other serial devices in the manuals of the respective device vendor.
  • Page 147: Hardware Configuration

    2. Select the user mode "FB 45" or "Ident profile". 3. Set all other parameters as required. Please note the specifications in the next paragraph. 4. Download the configuration to the controller. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 148 By scanning the code, all relevant parameters for the communication between the communications module and the optical handheld reader are set: • Interface: RS232 • Transmission speed: 115.2 kBd • Data bits: 8 • Parity: None • Stop bits: 1 SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 149: Functions And Commands

    No length information in the result; max. net data 233 bytes Write Sending data The address must be specified as "0xFFFF". Max. net data 233 bytes (without length information); no error message if the length is exceeded SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 150 The presence bit ("TP" or "ANZ_MDS_present") indicates that the CM has received new data and that this data is available for fetching with a "Read" command. After data transmission to the controller, the presence bit is reset unless new data has already been received. SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 151: Block-Specific Error Messages

    0xE4FE8D00 Internal communication error 0xE5FE0400 Invalid data block number (DBN) on the reader/communication module 0xE6FE0100 Unknown command, incorrect command parameters or unauthorized command chaining (incorrect length specification) 0xE6FE0500 "Reset_Reader" necessary SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 152: Ordering Data

    6XV1801-6DN10 15 m 6XV1801-6DN15 Power supply cable 0.5 m 6XV1801-6GE50 L-coded, 4-pin 1.0 m 6XV1801-6GH10 M12-90 1.5 m 6XV1801-6GH15 2.0 m 6XV1801-6GH20 3.0 m 6XV1801-6GH30 5.0 m 6XV1801-6GH50 10 m 6XV1801-6GN10 15 m 6XV1801-6GN15 SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 153 Connection cable for wide-range power supply 6GT2091-0PH50 L-coded, 4-pin / A-coded, 4-pin M12-180 / M12-180 Terminating resistor for PROFIBUS interface 6GK1905-0EC00 M12 sealing caps 3RX9802-0AA00 for unused connections (10 units) Usable as of product version "02" SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 154: Certificates & Approvals

    SIMATIC NET/SIMATIC Ident products are regularly submitted to the authorities and approval centers for approvals relating to certain markets and applications. Contact your Siemens representative if you need a list of the current approvals for the individual devices or check the Internet pages of Siemens Industry Online Support: Current approvals (https://support.industry.siemens.com/cs/ww/en/ps/15728/cert)
  • Page 155 File E85972 USA (FCC) This device complies with part 15 of the FCC rules. Importer UK: Siemens plc, Sir William Siemens House, Princess Road, Manchester M20 2UR EAC (Eurasian Conformity) Eurasian Economic Union of Russia, Belarus, Armenia, Kazakhstan and Kyrgyzstan...
  • Page 156 Appendix A.5 Certificates & approvals SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 157: Syslog Messages

    The "sysUpTime" parameter is metainformation about the message. It specifies the time (in hundredths of a second) since the last reinitialization of the network management part of the system. MESSAGE Message as ASCII string (English) SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 158: Variables In Syslog Messages

    Administrator | User | OPC {Time Number of seconds second} {Max Maximum number of sessions sessions} {Url} URL of the Web server that was accessed. /Engineering/Reset2Factor y?r=0.685644556250803 {Config Character string (with spaces) for the configuration. Power detail} SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 159: List Of Syslog Messages

    Standard IEC 62443-3-3 Reference: n/a (NERC-CIP 007-R5) User account management Message text Authentication was enabled. Example Authentication was enabled. Explanation Authentication was enabled. Severity Notice Facility local0 Standard IEC 62443-3-3 Reference: SR 1.3 SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 160 {Protocol}: User {User}: Access to url {url} denied. Example WBM: User admin: Access to url /Engineering/Reset2Factory?r=0.6856445562508033 denied. Explanation Access to Web resource was denied. Severity Error Facility local0 Standard IEC 62443-3-3 Reference: SR 2.1 SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 161 Message text {Protocol}: User {User name} has changed {Config detail} configuration. Example OPC: User admin has changed Power configuration. Explanation User has changed specific configuration. Severity Info Facility local0 Standard IEC 62443-3-3 Reference: SR 2.12 SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 162 Notice Facility local0 Standard IEC 62443-3-3 Reference: SR 7.4 Message text {Protocol}: Firmware activation failed. Example WBM: Firmware activation failed. Explanation Firmware activation failed. Severity Error Facility local0 Standard IEC 62443-3-3 Reference: SR 7.4 SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...
  • Page 163: Service & Support

    Industry Online Support In addition to the product documentation, you are supported by the comprehensive online information platform of Siemens Industry Online Support at the following Internet address: Link: (https://support.industry.siemens.com/cs/de/en/) Apart from news, you will also find the following there: •...
  • Page 164 Service & Support SIMATIC RF166C Operating Instructions, 03/2022, C79000-G8976-C578-02...

Table of Contents