Special Tools
Multimeter
Obtain this tool locally
The meter can test the electrical components and circuits for
current, resistance, or voltage.
Note: Use a digital multimeter when testing the electrical
circuits. The high impedance (internal resistance) of a digital
meter in the voltage mode ensures that the excess current
is not allowed through the meter. This excess current can
damage the circuits that are not designed to carry it.
Dielectric Gel
Toro Part No. 107-0342
Use the dielectric gel to prevent corrosion of unsealed
connection terminals. To ensure complete coating of the
terminals, liberally apply the gel to the component and wire
harness connector, plug the connector into the component,
unplug the connector, apply the gel to both surfaces again,
and connect the harness connector to the component again.
The connectors must be fully packed with gel for effective
results.
Note: Do not use the dielectric gel on the sealed connection
terminals as the gel can unseat the connector seals during
assembly.
Spark Tester
K Line Part No. TOR4036
For testing electronic ignitions. Saves time because you will
know if the ignition is causing the problem on a non-starting
engine. The tester determines if ignition spark is present.
Gauge Bar Assembly
K Line Part No. 94–9010
Use gauge bar to verify height-of-cut adjustment.