5-1 Display Area and Settings

5-1 Display Area and Settings

Status indicators
@ RUN
@ ERR
@ L/A IN
@ L/A OUT

Node Address Setting

The rotary switches in the display area are used to set the EtherCAT node address.
5
The node address set on the rotary switches is read only once when the control power supply is
turned ON. Any changes made to the rotary switches after the power is turned ON are ignored.
Such changes are enabled only after the power supply is turned ON again.
Do not change the rotary switch setting after the turning ON the power supply.
The node address rotary switches can be set to between 00 and 99.
The node address used over the network is determined by the value set on the rotary switches.
If the node address is not between 00 and 99, a Node Address Setting Error (Error 88.0) will occur.
EtherCAT Slave Information File
Information on EtherCAT slave settings is stored in the ESI (EtherCAT Slave Information) file.
Information in this file is used by the master to configure the network and set communications
parameters. This information is in an XML file.
5-1
Rotary switch setting
00
01 to 99
Precautions for Correct Use
Reference
OMNUC G5-series AC Servomotors and Servo Drives User's Manual (with Built-in EtherCAT Communications)
ADR
x10
CN5
Connection to CJ1W-NC281/NC481/NC881
The Position Control Unit sets the node address.
The rotary switch setting is used as the node address.
Rotary switches for
node address setting
x1
Description