1. Quit the terminal program.
With the terminal program version -16 or later,
- press [F2] while pressing [Alt] and [Fn] keys.
With the version -15 or earlier,
- press [F2] while pressing [Fn] key.
The prompt, "A:\DP10\TERMINAL>", will appear on the screen.
2. Insert the floppy disk containing the terminal program into the FD drive.
3. Change to "B" drive by pressing keys,
- [B], [:], and [Enter], successively.
4. Turn off once and on again the DP-6 (main unit).
5. To update the main unit program,
- press keys, [N], [B], [D], [P], [I], [N], [S], [T], and [Enter] key, successively.
6. After a message "DP-10 File Update" has appeared,
- press [F1] key.
6. - Press [N], [B], [D], [P], [.], [E], [X], [E], and [Enter] keys successively for
"File Name".
If an error message "Timeover Err" appears, turn off and on again the DP-6 main
unit after pressing [Esc] key. Then, try again from step 6.
8. Wait about 5 minutes until the "%" of "File Data Transferring" display reaches 100%.
9. When "Transfer Complete" is displayed, the main unit program updating has finished.
10. Turn off once and on again power of the main and terminal units.
Confirming program version
To confirm the version of the main program, execute "[F6]:System ---> Self-Test".
The prompt, "B:\>", will appear.
D2-12
DP-6