Fujitsu ETERNUS DX S5 Series Operation Manual (Basic page 24

Hybrid storage systems
Hide thumbs Also See for ETERNUS DX S5 Series:
Table of Contents

Advertisement

1. Basic Operation
Using the FUNCTION Button/Setting Change Switches
ETERNUS DX60 S5/DX100 S5/DX200 S5
The ETERNUS DX is in maintenance status when the MAINTENANCE LED is green.
3
Use the FUNCTION button/switches to change the settings.
Switching the Master CM to the other controller when two controllers are installed
Use the pin to push the FUNCTION button/CM Master Change switch (MST SW) twice within three
seconds.
The MASTER LED for the controller that is set as the Master CM is green.
Restoring the factory default settings of the LAN ports
Use the pin to push the FUNCTION button/IP reset switch (IP RST SW) three times within three seconds.
After the default settings of the LAN ports are restored, the MAINTENANCE LED blinks green a few times
a second for several seconds.
Restoring the factory default user settings
(1)
Remove all the LAN cables from the LAN ports (MNT ports and RMT ports) of all the controllers.
(2)
Use the pin to push the FUNCTION button/IP reset switch (IP RST SW) five times within three
seconds.
After the default user settings are restored, the MAINTENANCE LED blinks green approximately every
second for several seconds.
4
Release maintenance status.
Use the pin to push the FUNCTION button/maintenance switch (MNT SW) for three seconds.
The MAINTENANCE LED turns off, which indicates that the ETERNUS DX is no longer in maintenance
status.
5
Attach the front cover or the front cover.
ETERNUS DX500 S5/DX600 S5/DX900 S5
24
Operation Guide (Basic)

Advertisement

Table of Contents
loading

Table of Contents