A. Component Names
Controller Enclosure
●
ETERNUS DX100 S5/DX200 S5
There are nine types of host interfaces: FC 32Gbit/s, FC 16Gbit/s, iSCSI 10Gbit/s (10GBASE-SR/10GBASE-CR),
iSCSI 10Gbit/s (10GBASE-T), iSCSI 1Gbit/s, SAS 12Gbit/s, Ethernet 10Gbit/s, and Ethernet 1Gbit/s.
Figure 45
FC 2 ports
FC 2 ports
iSCSI 10Gbit/s (10GBASE-SR)
LINK/FAULT LED
iSCSI 10Gbit/s (10GBASE-CR)
Ethernet 10Gbit/s
(for Copper Twinax cable connection)
LINK/FAULT LED
SAS 12Gbit/s
LINK/FAULT LED
The LEDs turn on or blink to indicate the statuses that are listed below.
Table 25
Status and Meaning of Each LED (Host Interface for the ETERNUS DX100 S5/DX200 S5)
LED name
LINK/FAULT
Host Interface Ports (ETERNUS DX100 S5/DX200 S5)
LINK/FAULT LED
FC 4 ports
LINK/FAULT LED
iSCSI 10Gbit/s (10GBASE-T)
iSCSI 1Gbit/s
LINK/FAULT LED
Ethernet 1Gbit/s
LED status
(green)
(amber)
LINK LED
FAULT LED
Meaning
The link between the host interface port (FC or SAS) and the
destination port has been established.
The host interface port (FC or SAS) is in error status.
117