A. Component Names
Controller Enclosure
■
Controllers
The controller contains a CPU, system memory, Battery Backup Unit (BBU), host interfaces, drive interface (DI)
ports, and LAN ports. The controller controls all operations in the ETERNUS DX.
●
ETERNUS DX60 S5
Figure 34
CA#0 FAULT LED
Figure 35
The LEDs turn on or blink to indicate the statuses that are listed below.
Table 18
Status and Meaning of Each LED (Controller for the ETERNUS DX60 S5)
LED name
IDENTIFY/BBU FAULT
DI (OUT) LINK/FAULT
LAN ACT
LAN LINK
Controller (for the ETERNUS DX60 S5, Pattern 1)
IDENTIFY/BBU FAULT LED
DI (OUT) LINK/FAULT LED
Controller (for the ETERNUS DX60 S5, Pattern 2)
IDENTIFY/BBU FAULT LED
CA#0 FAULT LED
DI (OUT) LINK/FAULT LED
LED status
(blinks blue)
(amber)
(green)
(amber)
(blinks amber)
(blinks green)
(green)
READY/FAULT LED
MASTER LED
LAN LINK LED
LAN ACT LED
READY/FAULT LED
MASTER LED
LAN LINK LED
LAN ACT LED
Meaning
The installation location of the controller is identified according to
the instruction that is issued from ETERNUS Web GUI or ETERNUS CLI.
The battery is in error status.
The link between the DI (OUT) port and the destination port has been
established.
The link between the DI (OUT) port and the destination port is in
•
error status.
The ports to remove the cables between enclosures from are
•
indicated. This occurs while a drive enclosure is being added.
The ports to connect the cables are indicated. This occurs while a
drive enclosure is being added.
Data is being sent or received via the LAN port.
The link between the LAN port and the destination port has been
established.
109
LAN LINK LED
LAN ACT LED
LAN LINK LED
LAN ACT LED
Operation Guide (Basic)