A. Component Names
Controller Enclosure
LED name
FAULT
LINK
ETERNUS DX500 S5/DX600 S5
There are seven types of host interfaces: FC 32Gbit/s, FC 16Gbit/s, iSCSI 10Gbit/s (10GBASE-SR / 10GBASE-CR),
iSCSI 1Gbit/s, Ethernet 10Gbit/s, and Ethernet 1Gbit/s.
Figure 46
CA FAULT LED
CA READY LED
FC 2 ports
iSCSI 10Gbit/s (10GBASE-SR)
Port#0 Port#1
iSCSI 10Gbit/s (10GBASE-CR)
Ethernet 10Gbit/s
(for Copper Twinax cable connection)
Port#0 Port#1
Ethernet 1Gbit/s
Port#0 Port#1 Port#2 Port#3
The states of LEDs are listed below.
Table 26
Status and Meaning of Each LED (Host Interface for the ETERNUS DX500 S5/DX600 S5)
LED name
CA FAULT
CA READY
LINK/FAULT
LED status
(green)
(amber)
Host Interface Ports (ETERNUS DX500 S5/DX600 S5)
LINK/FAULT LED
LINK/FAULT LED
LINK/FAULT LED
LED status
(amber)
(green)
(green)
(amber)
Meaning
The link between the host interface port (iSCSI) and the
destination port has been established.
The host interface port (iSCSI) is in error status.
FC 4 ports
LINK/FAULT LED
Port#0 Port#1
Port#2 Port#3
iSCSI 1Gbit/s
LINK/FAULT LED
Port#0 Port#1
Port#2 Port#3
Meaning
The host interface is in error status.
The host interface is in normal status.
The link between the host interface port and the destination
port has been established.
The host interface port is in error status.