Common procedures for installable features
Hide thumbs Also See for 5105-22E:

Advertisement

• No: If an SRN or other reference code is displayed, suspect a loose adapter or cable connection.
Review the procedures for the part that you replaced to ensure that the new part is installed
correctly. If you cannot correct the problem, collect all SRNs or any other reference code
information that is displayed. If the system does not start or if login prompt is not displayed, see
Problems with loading and starting the operating system.
If the system is partitioned, note the logical partition in which you replaced the part. Contact your
service provider for assistance.
• Yes: Go to step "4" on page 91.
4. At the command prompt, type diag —a and press Enter to check for missing resources.
If you see a command prompt, go to step "5" on page 91.
If the Diagnostic selection menu is shown with M appearing next to any resource, complete the
following steps:
a) Select the resource and press Enter.
b) Select Commit.
c) Follow any instructions that are shown.
d) If a Do you want to review the previously displayed error? message is shown, select Yes and press
Enter.
e) If an SRN is shown, suspect a loose card or connection. If no obvious problem is shown, record
the SRN and contact your service provider for assistance.
f) If no SRN is shown, go to "5" on page 91.
5. To test the part, complete the following steps:
a) On the command line, type diagmenu and press Enter.
b) From the Function Selection menu, select Advanced Diagnostics Routines and press Enter.
c) From the Diagnostic Mode Selection menu, select System Verification and press Enter.
d) Select All Resources, or select the diagnostics for the individual part to test only the part you
replaced, and any devices that are attached to the part you replaced and press Enter.
Did the Resource Repair Action menu appear?
• No: Go to step "6" on page 91.
• Yes: Go to step "7" on page 91.
6. Did the Testing Complete, No trouble was found message appear?
• No: There is still a problem. Contact your service provider. This ends the procedure.
• Yes: Select Log Repair Action, if not previously logged, from the Task Selection menu to update
the error log. If the repair action was reseating a cable or adapter, select the resource associated
with that repair action. If the resource associated with your action is not displayed on the
Resource List, select sysplanar0 and press Enter.
Tip: This action changes the indicator light for the part from the fault state to the normal state.
Go to step "9" on page 92.
7. Select the resource for the replaced part from the Resource Repair Action menu. When a test is run
on a resource in system verification mode, and that resource has an entry in the error log, if the test
on the resource was successful, the Resource Repair Action menu appears. Complete the following
steps to update the error log to indicate that a system-detectable part has been replaced. On
systems with a indicator light for the failing part, this changes the indicator light to the normal state.
a) Select the resource that has been replaced from the Resource Repair Action menu. If the repair
action was reseating a cable or adapter, select the resource associated with that repair action. If
the resource associated with your action does not appear in the Resource List, select sysplanar0.
Press Enter.
b) Select Commit after you make your selections. Did another Resource Repair Action display
appear?
Common procedures for installable features 91