c. Select Set All Identify Indicators to NORMAL and press Enter.
d. Choose Commit.
Note: This changes the system attention and identify indicators from the Fault state to the Normal
state.
e. Exit to the command line.
Verifying an installed part or replaced part on a system or logical partition by using Virtual I/O Server
tools
If you installed or replaced a part, you might want to use the tools in Virtual I/O Server (VIOS) to verify
that the part is recognized by the system or logical partition.
Verifying an installed part by using the VIOS
You can verify the operation of an installed part by using the VIOS.
Procedure
1. Log in as root user.
2. On the command line, type diagmenu and press Enter.
3. Select Advanced Diagnostics Routines and press Enter.
4. From the Diagnostic Mode Selection menu, select System Verification and press Enter.
5. When the Advanced Diagnostic Selection menu appears, complete one of the following steps:
• To test a single resource, select the resource that you just installed from the list of resources and
press Enter.
• To test all the resources available to the operating system, select All Resources and press Enter.
6. Select Commit, and wait until the diagnostic programs run to completion, responding to any prompts
that appear.
7. Did the diagnostics run to completion and display the message No trouble was found?
• No: If a service request number (SRN) or other reference code is displayed, suspect a loose adapter
or cable connection. Review the installation procedures to ensure that the new part is installed
correctly. If you cannot correct the problem, collect all SRNs or any other reference code
information that is displayed. If the system is running in LPAR mode, note the logical partition in
which you installed the part. Contact your service provider for assistance.
• Yes: The new device is installed correctly. Exit the diagnostic programs and return the system to
normal operations.
Verify the replacement part by using the VIOS
You can verify the operation of a replacement part by using the VIOS.
Procedure
1. Did you replace the part by using either the VIOS or the online diagnostics service aid's concurrent
(hot-swap) service operation?
• No: Go to step "2" on page 90.
• Yes: Go to step "5" on page 91.
2. Is the system powered off?
• No: Go to step "4" on page 91.
• Yes: Go to step "3" on page 90.
3. Start the system and wait until the VIOS operating system login prompt displays or until apparent
system activity on the operator panel or display has stopped.
Did the VIOS login prompt display?
90 Power Systems: Common procedures for installable features