a. Push the release latches (A) in the direction shown in the following figure.
b. Slide the cover (B) off the system unit as shown in the following figure. When the front of the
service access cover has cleared the upper frame ledge, lift the cover up and off the system unit.
Figure 36. Removing the service access cover
Installing the service access cover on the 9040-MR9 system
Use this procedure to install the service access cover on the IBM Power System E950 (9040-MR9) server.
Procedure
1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged
into a ground jack or connected to an unpainted metal surface. If not, do so now.
2. Complete the following steps to replace the service access cover; refer to the following figure.
a) Lower the cover (A) onto the system unit. Ensure that the cover alignment pins (C) on each side of
the cover fit into the matching slots in the chassis.
b) Slide the cover (A) onto the system unit. Ensure that the tabs (D) tuck under the mesh along the
front opening of the chassis.
c) Close the release latches (B) by pushing it in the direction that is shown in the following figure.
Common procedures for installable features 51