Page 1
Power Systems Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S...
Page 2
Note Before using this information and the product it supports, read the information in “Safety notices” on page v, “Notices” on page 27, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. ®...
9223-42H, or 9223-42S ........................8 Adapter placement rules and slot priorities for the EMX0 PCIe Gen3 I/O expansion drawer....16 Related procedures for adapter placement....................24 Finding the current system configuration in IBM i................24 Notices........................27 Accessibility features for IBM Power Systems servers................28 Privacy policy considerations ........................
Das Produkt ist nicht für den Einsatz an Bildschirmarbeitsplätzen im Sinne § 2 der Bildschirmarbeitsverordnung geeignet. Laser safety information IBM servers can use I/O cards or features that are fiber-optic based and that utilize lasers or LEDs. Laser compliance IBM servers may be installed inside or outside of an IT equipment rack.
Page 6
• Each rack cabinet might have more than one power cord. – For AC powered racks, be sure to disconnect all power cords in the rack cabinet when directed to disconnect power during servicing. vi Power Systems: Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S...
Page 7
– For racks with a DC power distribution panel (PDP), turn off the circuit breaker that controls the power to the system unit(s), or disconnect the customer’s DC power source, when directed to disconnect power during servicing. • Connect all devices installed in a rack cabinet to power devices installed in the same rack cabinet.
Page 8
(for example, when working from a ladder). Stability hazard: • The rack may tip over causing serious personal injury. • Before extending the rack to the installation position, read the installation instructions. viii Power Systems: Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S...
Page 9
• Do not put any load on the slide-rail mounted equipment mounted in the installation position. • Do not leave the slide-rail mounted equipment in the installation position. (L002) (L003) Safety notices ix...
Page 10
There are no serviceable parts inside the device. • Use of the controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure. (C026) x Power Systems: Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S...
Page 11
Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call.
Page 12
Freewheeling will cause uneven cable wrapping around winch drum, damage cable, and may cause serious injury. • This TOOL must be maintained correctly for IBM Service personnel to use it. IBM shall inspect condition and verify maintenance history before operation. Personnel reserve the right not to use TOOL if inadequate.
Page 13
The dc-powered system employs an isolated DC return (DC-I) design. The DC battery return terminal shall not be connected to the chassis or frame ground. The dc-powered system is intended to be installed in a common bonding network (CBN) as described in GR-1089-CORE.
Page 14
Systems: Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S...
9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S system. Slot descriptions for the 9009-41G, 9009-42G, or 9223-42S The 9009-41G, 9009-42G, and 9223-42S systems provide PCIe4 slots. The 9009-41G system offers one POWER9 processor module. The 9009-42G and 9223-42S systems offers two POWER9 processor modules.
Page 16
Figure 1 on page 3 shows the rear view of the system with the location codes for the PCIe4 adapter slots. Table 4 on page 3 lists the PCIe4 adapter slot locations and details for the 9009-41G, 9009-42G, and 9223-42S systems. 2 Power Systems: Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S...
Page 17
Figure 1. Rear view of a rack-mounted 9009-41G, 9009-42G, or 9223-42S system with PCIe4 slots location codes Table 4. Slot locations and descriptions for the 9009-41G, 9009-42G, or 9223-42S system Location Descriptio Process Adapter Slot capabilities Slot availability code size...
Page 18
Table 4. Slot locations and descriptions for the 9009-41G, 9009-42G, or 9223-42S system (continued) Location Descriptio Process Adapter Slot capabilities Slot availability code size CAPI 32-bit I/O adapter enlarged capacity 9009-41G, 9009-42G and module enablement order 3 (9009-42G dynamic adapter...
Page 19
Supported Aggregate full duplex bandwidth 768 GT/s Designate any port as the upstream port 27x27 mm, 676-pin FCBGA package Power consumption • Nominal: 8 watts • Maximum: 12 watts Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S 5...
Page 20
(two access capacit (one processors) (DMA) processor) enable ment order 5 (9009-4 P1-C2 1, 3 PCIe4 x8 or Processor Full- NVLink slot module height, SCM1 half- length 6 Power Systems: Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S...
Page 21
• The peak bandwidths supported by P1-C2 and P1-C8 x8 slots are 16 GBps in simplex mode and 32 GBps in duplex mode. • All slots support enhanced error handling (EEH). • All PCIe slots are hot swappable and support concurrent maintenance. Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S 7...
Use this information while selecting slots for installing adapters in the 9009-41G, 9009-42G, or 9223-42S system. Use Table 8 on page 9 to identify slot placement priorities in the system and the maximum number of adapters that can be installed in the system.
Page 23
Note: In the following table, the slot priority numbers 2 - 12 correspond to slot locations P1-C2 through P1-C12. Table 8. Adapter slot priorities and maximum adapters supported in the 9009-41G, 9009-42G, or 9223-42S Feature Description 9009-41G, 9009-42G, or 9223-42S...
Page 24
Table 8. Adapter slot priorities and maximum adapters supported in the 9009-41G, 9009-42G, or 9223-42S (continued) Feature Description 9009-41G, 9009-42G, or 9223-42S 9009-42G or 9223-42S code (one processor) (two processors) Slot priorities Maximum number Slot priorities Maximum number of adapters...
Page 25
Table 8. Adapter slot priorities and maximum adapters supported in the 9009-41G, 9009-42G, or 9223-42S (continued) Feature Description 9009-41G, 9009-42G, or 9223-42S 9009-42G or 9223-42S code (one processor) (two processors) Slot priorities Maximum number Slot priorities Maximum number of adapters...
Page 26
Table 8. Adapter slot priorities and maximum adapters supported in the 9009-41G, 9009-42G, or 9223-42S (continued) Feature Description 9009-41G, 9009-42G, or 9223-42S 9009-42G or 9223-42S code (one processor) (two processors) Slot priorities Maximum number Slot priorities Maximum number of adapters...
Page 27
00E2932 EC5B PCIe3 x8 Non-Volatile Memory 1.6 TB SSD 8, 9, 5 2, 8, 3, 9, 4 NVMe adapter (FC EC5A and EC5B; CCIN 58FC); Adapter part number: 01DH570 Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S 13...
Page 28
PCIe3 12 GB Cache SAS RAID quad-port 6 Gb 8, 9, 5, 10, 6, 12, 7 8, 2, 4, 9, 3, 5, 10, adapter (FC EJ0L; CCIN 57CE); Adapter part 6, 12, 7 number: 00FX840 14 Power Systems: Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S...
Page 29
PCIe3 x8 4-port Fibre Channel (16 Gb/s); (FC 8, 9, 5, 10, 6, 12, 7 8, 2, 4, 9, 3, 5, 10, EL5W, EL5X, EN1C, and EN1D; CCIN 578E); 6, 12, 7 Adapter part number: 01FT698 Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S 15...
PCIe3 6-slot fanout module. Table 10 on page 17 lists the adapter slot locations and details for the EMX0 PCIe3 expansion drawer. 16 Power Systems: Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S...
Page 32
• If the EMX0 PCIe3 expansion drawer is configured with two PCIe3 6-slot fanout modules, distribute the adapters across both I/O modules whenever possible. 18 Power Systems: Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S...
Page 33
2 or 6 2 or 6 SR/Cu adapter (FC EC2R and C5, P2-C5, P1-C3, EC2S; CCIN 58FA); Adapter part P2-C3, P1-C6, P2- number: 01FT759 C6, P1-C1, P2-C1, P1-C4, P2-C4 Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S 19...
Page 34
EMX0 PCIe3 expansion drawer code Slot priorities Maximum number of adapters supported ® Linux IBM i EC2U PCIe3 2-port 25/10 Gb NIC & P1-C2, P2-C2, P1- 2 or 6 2 or 6 2 or 6 RoCE SFP28 adapter (FC EC2T C5, P2-C5, P1-C3, and EC2U;...
Page 35
6 (EL5B - 6 (EL5B - Channel adapter (FC EL5B and C4, P2-C4, P1-C2, EN0A; CCIN 577F); Adapter part P2-C2, P1-C3, P2- number: 00E3496 C3, P1-C5, P2-C5, P1-C6, P2-C6 Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S 21...
Page 36
EMX0 PCIe3 expansion drawer code Slot priorities Maximum number of adapters supported ® Linux IBM i EN0A PCIe3 16 Gb 2-port Fibre P1-C1, P2-C1, P1- Channel adapter (FC EL43, C4, P2-C4, P1-C2, EL5B, EN0A, and EN0B; CCIN P2-C2, P1-C3, P2- 577F);...
Page 37
PCIe4 x8 2-port Fibre Channel P1-C2, P2-C2, P1- (32 Gb/s); (FC EN1J and C5, P2-C5, P1-C3, EN1K; CCIN 579C); Adapter part P2-C3, P1-C6, P2- number: 02CM909 C6, P1-C1, P2-C1, P1-C4, P2-C4 Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S 23...
About this task To find the current system configuration, start an IBM i session and sign on. If you have more than one system, start a session on the system that is being upgraded and for which you have service tools authority.
Page 39
Type 9 for the System Expansion Unit field and press Enter. b. Repeat steps 7-11 for each expansion unit. c. Select an available slot in the expansion unit. Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S 25...
Page 40
26 Power Systems: Adapter placement for the 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S...
Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
This product uses standard navigation keys. Interface information The IBM Power Systems servers user interfaces do not have content that flashes 2 - 55 times per second. The IBM Power Systems servers web user interface relies on cascading style sheets to render content properly and to provide a usable experience.
Contact the vendor for accessibility information about its products. Related accessibility information In addition to standard IBM help desk and support websites, IBM has a TTY telephone service for use by deaf or hard of hearing customers to access sales and support services:...
Page 44
Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
Page 45
Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 / EN 55032 Klasse A. Japan Electronics and Information Technology Industries Association (JEITA) Notice This statement applies to products less than or equal to 20 A per phase. This statement applies to products greater than 20 A, single phase.
Page 46
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
Page 48
Tel: +49 (0) 800 225 5426 email: HalloIBM@de.ibm.com Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55032 Klasse B Japan Electronics and Information Technology Industries Association (JEITA) Notice This statement applies to products less than or equal to 20 A per phase.
Permissions for the use of these publications are granted subject to the following terms and conditions. Applicability: These terms and conditions are in addition to any terms of use for the IBM website. Personal Use: You may reproduce these publications for your personal, noncommercial use provided that all proprietary notices are preserved.
Page 50
IBM reserves the right to withdraw the permissions granted herein whenever, in its discretion, the use of the publications is detrimental to its interest or, as determined by IBM, the above instructions are not being properly followed. You may not download, export or re-export this information except in full compliance with all applicable laws and regulations, including all United States export laws and regulations.