Download Print this page

IBM 5105-22E Manual page 51

Common procedures for installable features
Hide thumbs Also See for 5105-22E:

Advertisement

CAUTION: The fans can pull in hair, jewelry, loose clothing, and so forth, and cause injury or
damage. Operate the system with the bezel installed. For service operations, if the front cover
must be removed with the system operating, ensure that all such loose material is secured
away from the fan area, to prevent any loose material from being pulled into the fan.
Figure 34. Removing the front cover
Installing the front cover on a 9040-MR9 system
Use this procedure to install the cover on a IBM Power System E950 (9040-MR9) server.
Procedure
1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged
into a ground jack or connected to an unpainted metal surface. If not, do so now.
2. Position the cover (A) on the front of the system unit as shown in the following figure, so that the four
pins (B) on the system match the four holes at the rear of the cover.
Press the tabs (C) to snap the cover into position.
Common procedures for installable features 49

Advertisement

loading