Power Systems
PCIe adapters for the 9009-41A,
9009-42A, or 9223-42H
IBM

Advertisement

Table of Contents
loading

Summary of Contents for IBM 9009-41A

  • Page 1 Power Systems PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 2 Note Before using this information and the product it supports, read the information in “Safety notices” on page v, “Notices” on page 103, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. ®...
  • Page 3: Table Of Contents

    Preparing the 9009-41A, 9009-42A, or 9223-42H system to install a PCIe adapter......1 Installing a PCIe adapter in the 9009-41A, 9009-42A, and 9223-42H..........17 Preparing the 9009-41A, 9009-42A, or 9223-42H system for operation after installing a PCIe adapter............................19 Removing and replacing PCIe adapters in the system................28 Preparing the 9009-41A, 9009-42A, or 9223-42H system to remove and replace a PCIe adapter............................
  • Page 5: Safety Notices

    Das Produkt ist nicht für den Einsatz an Bildschirmarbeitsplätzen im Sinne § 2 der Bildschirmarbeitsverordnung geeignet. Laser safety information IBM servers can use I/O cards or features that are fiber-optic based and that utilize lasers or LEDs. Laser compliance IBM servers may be installed inside or outside of an IT equipment rack.
  • Page 6 • To avoid hazardous conditions due to uneven mechanical loading, always install the heaviest devices in the bottom of the rack cabinet. Always install servers and optional devices starting from the bottom of the rack cabinet. vi Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 7 • Rack-mounted devices are not to be used as shelves or work spaces. Do not place objects on top of rack-mounted devices. In addition, do not lean on rack mounted devices and do not use them to stabilize your body position (for example, when working from a ladder). •...
  • Page 8 DANGER: Hazardous voltage, current, or energy levels are present inside any component that has this label attached. Do not open any cover or barrier that contains this label. (L001) (L002) viii Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 9 DANGER: Rack-mounted devices are not to be used as shelves or work spaces. Do not place objects on top of rack-mounted devices. In addition, do not lean on rack-mounted devices and do not use them to stabilize your body position (for example, when working from a ladder). Stability hazard: •...
  • Page 10 DANGER: Multiple power cords. The product might be equipped with multiple AC power cords or multiple DC power cables. To remove all hazardous voltages, disconnect all power cords and power cables. (L003) (L007) CAUTION: A hot surface nearby. (L007) x Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 11 Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call.
  • Page 12 Be sure winch is locked in position before releasing handle. Read instruction page before operating this winch. Never allow winch to unwind freely. xii Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 13 Freewheeling will cause uneven cable wrapping around winch drum, damage cable, and may cause serious injury. • This TOOL must be maintained correctly for IBM Service personnel to use it. IBM shall inspect condition and verify maintenance history before operation. Personnel reserve the right not to use TOOL if inadequate.
  • Page 14 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 15: Installing, Removing, And Replacing Pcie Adapters

    If your system is not managed by an HMC, complete the steps in the following procedures to install a PCIe adapter in the system. Preparing the 9009-41A, 9009-42A, or 9223-42H system to install a PCIe adapter To prepare the system to install a PCIe adapter, complete the steps in this procedure.
  • Page 16 The number of the PCIe adapter slots that are available in the system depends on the number of system processors in the system. For the PCIe adapter placement information in this system, see PCIe adapter placement rules and slot priorities for the 9009-41A, 9009-42A, or 9223-42H. The PCIe adapter has two LEDs that indicate the status: •...
  • Page 17 Figure 1. PCIe adapter slot locations and locations of the LEDs in a rack-mounted 9009-41A, 9009-42A, and 9223-42H system Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 3...
  • Page 18 “9” on page 9. • If the system power is turned on and if the IBM i operating system controls the slot, continue with step “10” on page 10. • If the system power is turned on and if the Linux operating system controls the slot, continue with step “11”...
  • Page 19 Stop the system. For instructions, see Stopping a system (www.ibm.com/support/ knowledgecenter/POWER9/p9haj/crustopsys.htm). 8. If you powered the system off, complete the following steps: a) Label and disconnect the power cords from the system unit. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 5...
  • Page 20 • The power cord (B) is fastened to the system with hook-and-loop fastener (A). If you are placing the system in a service position after you disconnect the power cords, ensure that you unstrap the fastener. Figure 4. Removing the power cords from a rack-mounted server 6 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 21 Figure 5. Removing the power cords from a stand-alone server (L003) Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 7...
  • Page 22 8 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 23 1) Release the mounting bracket from the cable management arm assembly by pressing the indentation (A) on the inner cable management arm tab. The cable management arm releases from the outer mounting bracket in the direction shown. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 9...
  • Page 24 Continue with step “12” on page 13. 10. To prepare the system to install a PCIe adapter by using the IBM i operating system, complete the following steps: a) If necessary, start a System Service Tools (SST) session by typing strsst on the command line of the Main Menu and then press Enter.
  • Page 25 (A) on the inner cable management arm tab. The cable management arm releases from the outer mounting bracket in the direction shown. Figure 7. Releasing the mounting bracket 2) Swing the cable management arm away from the system. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 11...
  • Page 26 1) Release the mounting bracket from the cable management arm assembly by pressing the indentation (A) on the inner cable management arm tab. The cable management arm releases from the outer mounting bracket in the direction shown. 12 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 27 Insert the inner cable management arm tab (A) into the outer mounting bracket (B) until it clicks into place as shown. The inner mounting bracket (C) is not used on the left side. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 13...
  • Page 28 Do not pull out or install any drawer or feature if the rack stabilizer brackets are not attached to the rack. Do not pull out more than one drawer at a time. The rack might become unstable if you pull out more than one drawer at a time. 14 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 29 5 seconds before you continue with the service process. 16. Remove the service access cover. For a rack-mounted system, complete the following steps. Refer to Figure 11 on page 16. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 15...
  • Page 30 Slide the cover (B) off the system unit. When the front of the service access cover has cleared the upper frame ledge, lift the cover up and off the system unit. 16 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 31: Installing A Pcie Adapter In The 9009-41A, 9009-42A, And 9223-42H

    See Figure 13 on page 18 and Figure 14 on page 19 for the location of the adapter latch. (L007) Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 17...
  • Page 32 See Figure 13 on page 18 and Figure 14 on page 19. 7. To lock the adapter in its slot, rotate the adapter latch (B) in the direction that is shown. Figure 13. Installing or replacing a PCIe adapter in a 9009-41A, 9009-42A, or 9223-42H rack- mounted system...
  • Page 33: Preparing The 9009-41A, 9009-42A, Or 9223-42H System For Operation After Installing A Pcie Adapter

    For a rack-mounted system, complete the following steps. Refer to Figure 15 on page 20. a. Slide the cover (A) onto the system unit. b. Close the release latch (B) by pushing it in the direction shown. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 19...
  • Page 34 For a stand-alone system, complete the following steps. Refer to Figure 16 on page 21. a. Slide the cover (B) on to the system unit as shown. b. Close the latch release (A) by pushing it in the direction shown. 20 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 35 Ensure that the cable management arms can move freely. Ensure that the cables at the rear of the unit do not catch or bind as you push the unit into the operating position. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 21...
  • Page 36 Release the mounting bracket from the cable management arm assembly by pressing the indentation (A) on the inner cable management arm tab. The cable management arm releases from the outer mounting bracket in the direction shown. 22 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 37 Fasten the power cords (A) to the system using the hook-and-loop fasteners (B) as shown in Figure 19 on page 24 or Figure 20 on page 25. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 23...
  • Page 38 Figure 19. Connecting the power cords to a rack-mounted system 24 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 39 Insert the inner cable management arm tab (A) into the outer mounting bracket (B) until it clicks into place as shown. The inner mounting bracket (C) is not used on the left side. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 25...
  • Page 40 • If you are using the AIX operating system, continue with step “14” on page 26. • If you are using the IBM i operating system, continue with step “15” on page 27. • If you are using the Linux operating system, continue with step “19” on page 27.
  • Page 41 15. If you are using the IBM i operating system, return to the Hardware Resource Concurrent Maintenance display and select Power on domain. The message Power on complete is shown. 16. Did you replace a PCIe3 x8 non-volatile memory SSD NVMe adapter? •...
  • Page 42: Removing And Replacing Pcie Adapters In The System

    21. Turn off the identify LED. For instructions, see Deactivating an identify LED (www.ibm.com/support/ knowledgecenter/POWER9/p9haj/p9haj_turn_off_identify_led.htm). Removing and replacing PCIe adapters in the 9009-41A, 9009-42A, and 9223-42H system Find information about removing and replacing a Peripheral Component Interconnect Express (PCIe) adapter in the IBM Power System E950 (9040-MR9).
  • Page 43 Attention: If the PCIe adapter is operating correctly, then the Activity LED is ON (green) and the Error amber LED is OFF, as shown in (B). Do not attempt to remove a working PCIe adapter. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 29...
  • Page 44 Figure 22. PCIe adapter slot locations and locations of the LEDs in a rack-mounted 9009-41A, 9009-42A, and 9223-42H system 30 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 45 • If the system power is turned on and if the AIX operating system controls the slot, continue with step “7” on page 36. • If the system power is turned on and if the IBM i operating system controls the slot, continue with step “8” on page 37.
  • Page 46 If you have not yet recorded the PCIe slot details, record the slot number and location of each adapter that is being removed. Note: Adapter slots are numbered on the rear of the system. 32 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 47 Figure 25. Removing the power cords from a rack-mounted server Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 33...
  • Page 48 Figure 26. Removing the power cords from a stand-alone server (L003) 34 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 49 Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 35...
  • Page 50 If necessary to view the identify LEDs or to manage cables at the rear of a rack-mounted system, open the cable management arm by completing the following steps: 36 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 51 Continue with step “10” on page 42. 8. To prepare to remove a PCIe adapter by using the IBM i operating system, complete the following steps: Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 37...
  • Page 52 Ensure that any processes or applications that might use the adapter are stopped. f) To identify the location of the failed PCIe adapter by using the IBM i operating system, complete the following steps: 1) Type strsst on the command line of the Main Menu and then press Enter.
  • Page 53 To deactivate the Identify LED, select Toggle LED blink off/on > Power off domain. Wait for the Hardware Resource Concurrent Maintenance display to appear with this message: Power off complete. j) Continue with step “10” on page 42. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 39...
  • Page 54 1) Release the mounting bracket from the cable management arm assembly by pressing the indentation (A) on the inner cable management arm tab. The cable management arm releases from the outer mounting bracket in the direction shown. 40 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 55 Use the Linux operating system drmgr command to prepare the adapter to be removed when the system power is turned on. 1) Type the following command: drmgr -c pci -r -s locationcode Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 41...
  • Page 56 Insert the inner cable management arm tab (A) into the outer mounting bracket (B) until it clicks into place as shown. The inner mounting bracket (C) is not used on the left side. 42 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 57 Do not pull out more than one drawer at a time. The rack might become unstable if you pull out more than one drawer at a time. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 43...
  • Page 58 5 seconds before you continue with the service process. 15. Remove the service access cover. For a rack-mounted system, complete the following steps. Refer to Figure 32 on page 45. 44 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 59 Slide the cover (B) off the system unit. When the front of the service access cover has cleared the upper frame ledge, lift the cover up and off the system unit. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 45...
  • Page 60: Removing A Pcie Adapter From The 9009-41A, 9009-42A, Or 9223-42H System

    Figure 33. Removing the service access cover Removing a PCIe adapter from the 9009-41A, 9009-42A, or 9223-42H system To remove a PCIe adapter from the system, complete the steps in this procedure. Procedure 1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged into a ground jack or connected to an unpainted metal surface.
  • Page 61 Attention: A pin on the tailstock of the adapter resembles a removable screw. Do not remove this pin. It is required for correct alignment and seating. Figure 34. Removing a PCIe adapter from a 9009-41A, 9009-42A, or 9223-42H rack-mounted system Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 47...
  • Page 62: Replacing A Pcie Adapter In The 9009-41A, 9009-42A, Or 9223-42H System

    Figure 35. Removing a PCIe adapter from the 9009-41A stand-alone system 4. Place the removed adapter on an approved ESD surface. Replacing a PCIe adapter in the 9009-41A, 9009-42A, or 9223-42H system To replace a PCIe adapter in the system, complete the steps in this procedure.
  • Page 63 • If the system power is turned on and you are using the IBM i operating system, continue with step “11” on page 49. • If you are using the AIX or Linux operation system, read the following note: Important: You need to work with the system administrator to prepare the PCI slot to receive the adapter.
  • Page 64 13. To lock the adapter in its slot, rotate the adapter latch (B) in the direction that is shown. Figure 36. Installing or replacing a PCIe adapter in a 9009-41A, 9009-42A, or 9223-42H rack- mounted system 50 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 65: Preparing The System For Operation After Removing And Replacing A Pcie Adapter

    For a rack-mounted system, complete the following steps. Refer to Figure 38 on page 52. a. Slide the cover (A) onto the system unit. b. Close the release latch (B) by pushing it in the direction shown. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 51...
  • Page 66 For a stand-alone system, complete the following steps. Refer to Figure 39 on page 53. a. Slide the cover (B) on to the system unit as shown. b. Close the latch release (A) by pushing it in the direction shown. 52 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 67 Ensure that the cable management arms can move freely. Ensure that the cables at the rear of the unit do not catch or bind as you push the unit into the operating position. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 53...
  • Page 68 Release the mounting bracket from the cable management arm assembly by pressing the indentation (A) on the inner cable management arm tab. The cable management arm releases from the outer mounting bracket in the direction shown. 54 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 69 Fasten the power cords (A) to the system using the hook-and-loop fasteners (B) as shown in Figure 42 on page 56 or Figure 43 on page 57. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 55...
  • Page 70 Figure 42. Connecting the power cords to a rack-mounted system 56 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 71 Insert the inner cable management arm tab (A) into the outer mounting bracket (B) until it clicks into place as shown. The inner mounting bracket (C) is not used on the left side. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 57...
  • Page 72 • If you are using the AIX operating system, continue with step “14” on page 58. • If you are using the IBM i operating system, continue with step “16” on page 59. • If you are using the Linux operating system, continue with step “20” on page 60.
  • Page 73 Press the F10 key to exit the diagnostic program. g) Continue with step “21” on page 60. 16. If you are using the IBM i operating system, return to the Hardware Resource Concurrent Maintenance display and select Power on domain.
  • Page 74: Permanently Removing A Pcie Adapter In The System

    • If you installed the part for any other reason, verify the installed part. For instructions, see https:// www.ibm.com/support/knowledgecenter/POWER9/p9haj/pxhaj_hsmverify.htm (www.ibm.com/ support/knowledgecenter/POWER9/p9haj/pxhaj_hsmverify.htm). 22. Turn off the identify LED. For instructions, see Deactivating an identify LED (www.ibm.com/support/ knowledgecenter/POWER9/p9haj/p9haj_turn_off_identify_led.htm). 23. If you replaced a Fibre Channel adapter, the customer might need to update the Fibre Channel SAS path to the external storage subsystems with the new WWPN number or numbers.
  • Page 75: Preparing The 9009-41A, 9009-42A, Or 9223-42H System To Permanently Remove A Pcie Adapter

    Attention: If the PCIe adapter is operating correctly, then the Activity LED is ON (green) and the Error amber LED is OFF, as shown in (B). Do not attempt to remove a working PCIe adapter. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 61...
  • Page 76 Figure 45. PCIe adapter slot locations and locations of the LEDs in a rack-mounted 9009-41A, 9009-42A, and 9223-42H system 62 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 77 Release the mounting bracket from the cable management arm assembly by pressing the indentation (A) on the inner cable management arm tab. The cable management arm releases from the outer mounting bracket in the direction shown. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 63...
  • Page 78 7. If you have not yet recorded the PCIe slot details, record the slot number and location of each adapter that is being removed. Note: Adapter slots are numbered on the rear of the system. 8. Stop the system. For instructions, see Stopping a system (www.ibm.com/support/knowledgecenter/ POWER9/p9haj/crustopsys.htm). 64 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 79 Figure 48. Removing the power cords from a rack-mounted server Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 65...
  • Page 80 Figure 49. Removing the power cords from a stand-alone server (L003) 66 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 81 Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 67...
  • Page 82 The inner mounting bracket (C) is not used on the left side. Figure 50. Closing the cable management arm 12. If applicable, open the rack front door. 68 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 83 Do not pull out more than one drawer at a time. The rack might become unstable if you pull out more than one drawer at a time. Figure 51. Releasing the side latches 14. Attach the electrostatic discharge (ESD) wrist strap. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 69...
  • Page 84 Slide the cover (B) off the system unit. When the front of the service access cover clears the upper frame ledge, lift the cover up and off the system unit. 70 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 85 Slide the cover (B) off the system unit. When the front of the service access cover has cleared the upper frame ledge, lift the cover up and off the system unit. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 71...
  • Page 86: Permanently Removing A Pcie Adapter From The 9009-41A, 9009-42A, Or 9223-42H System

    Figure 53. Removing the service access cover Permanently removing a PCIe adapter from the 9009-41A, 9009-42A, or 9223-42H system To permanently remove a PCIe adapter from the system, complete the steps in this procedure. Procedure 1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged into a ground jack or connected to an unpainted metal surface.
  • Page 87 Attention: A pin on the tailstock of the adapter resembles a removable screw. Do not remove this pin. It is required for correct alignment and seating. Figure 54. Removing a PCIe adapter from a 9009-41A, 9009-42A, or 9223-42H rack-mounted system Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 73...
  • Page 88 Figure 55. Removing a PCIe adapter from the 9009-41A stand-alone system 4. Place the removed adapter on an approved ESD surface. 5. After permanently removing a PCIe adapter, you must install a PCIe filler in the empty slot. To install a...
  • Page 89 Figure 56. Installing a filler in a PCIe adapter slot in the 9009-41A, 9009-42A, or 9223-42H rack- mounted system Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 75...
  • Page 90: Preparing The 9009-41A, 9009-42A, Or 9223-42H System For Operation After Permanently Removing A Pcie Adapter

    Figure 57. Installing a filler in the PCIe adapter slot in the 9009-41A stand-alone system Preparing the 9009-41A, 9009-42A, or 9223-42H system for operation after permanently removing a PCIe adapter To prepare the system for operation after permanently removing a PCIe adapter, complete the steps in this procedure.
  • Page 91 For a stand-alone system, complete the following steps. Refer to Figure 59 on page 78. a. Slide the cover (B) on to the system unit as shown. b. Close the latch release (A) by pushing it in the direction shown. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 77...
  • Page 92 Ensure that the cable management arms can move freely. Ensure that the cables at the rear of the unit do not catch or bind as you push the unit into the operating position. 78 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 93 Release the mounting bracket from the cable management arm assembly by pressing the indentation (A) on the inner cable management arm tab. The cable management arm releases from the outer mounting bracket in the direction shown. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 79...
  • Page 94 7. Using your labels, reconnect the power cords (A) to the system unit. Fasten the power cords (A) to the system using the hook-and-loop fasteners (B) as shown in Figure 62 on page 81 or Figure 63 on page 82. 80 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 95 Figure 62. Connecting the power cords to a rack-mounted system Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 81...
  • Page 96 Insert the inner cable management arm tab (A) into the outer mounting bracket (B) until it clicks into place as shown. The inner mounting bracket (C) is not used on the left side. 82 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 97: Related Procedures For Installing And Removing Pcie Adapters

    Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: • If IBM supplied the power cord(s), connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
  • Page 98 5. For racks with a DC power distribution panel (PDP), restore the power from the Customer's DC power source and turn on the circuit breakers located in the PDP. 6. Turn on the devices. 84 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 99: Handling Static-Sensitive Devices

    Updating the worldwide port name for a new 5735 IOA If you exchange a 5735 Fibre Channel input/output adapter (IOA), the IBM external storage subsystem must be updated to use the worldwide port name (WWPN) of the new 5735 IOA. Any SAN hardware that uses the WWPN zoning might also need updating.
  • Page 100 (SFP) transceivers, you must first remove the SFP transceivers. To remove the SFP transceivers, complete the following steps: a) Place the card flat on a static-protective surface. 86 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 101 8. Using a Phillips screwdriver, unscrew the two retaining screws (A) that attach the high-profile tailstock (B) to the new PCIe adapter, as shown in Figure 67 on page 88. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 87...
  • Page 102 14. Using a Phillips screwdriver and the two retaining screws (B), attach the tailstock (A) from the failed PCIe adapter onto the new PCIe adapter, as shown in Figure 68 on page 89. 88 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 103 With the latch (B) in the open position, push the latch by rotating it up and toward the card as shown in Figure 69 on page 90. d) Repeat for the other transceiver. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 89...
  • Page 104: Pcie Hot-Plug Manager Access For Aix

    This action prevents a service representative or user from causing an unexpected outage for system users. To access the hot-plug menus, complete the following steps: Procedure 1. Log in as root user. 90 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 105 If the instructions do not resolve the problem, do the following: • If the adapter is listed as Unknown, perform the Install/configure devices Added After IPL option to configure the adapter. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 91...
  • Page 106: Installing The Aix Device Driver Software

    About this task If you are installing only the device driver for a PCIe adapter, perform these steps: 92 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 107 Verify that the file sets are installed at the AIX version level you are running. Level 5.3.8.0 is an example. If no data is displayed on your screen, the adapter device driver was not installed correctly. Try reinstalling the driver. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 93...
  • Page 108: Installing Or Replacing A Pcie Adapter With The System Power Turned On In A Virtual I/O Server

    Action state. a. Set the adapter LED to the action state so that the indicator light for the adapter slot flashes b. Physically install the adapter 94 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 109 • Listing all slots that are currently in use or a slot that is occupied by a specific adapter • Identifying the adapter's slot location • Making parent and child devices unavailable • Making the adapter unavailable Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 95...
  • Page 110 Virtual I/O Server logical partitions that, in However, path errors might be logged on the client conjunction with virtual client adapters, provide logical partition. multiple paths to the physical volume on the client logical partition. 96 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 111: Verifying That The Hot-Plug Pci Tools Are Installed For Linux

    3. Ensure the following tools are available in the /usr/sbin directory. • lsslot • drmgr -c pci 4. Return to the procedure that sent you here. Installing, removing, and replacing PCIe adapters for the 9009-41A, 9009-42A, and 9223-42H system 97...
  • Page 112: Checking The Amount Of Remaining Life In Nvme Devices

    Learn how to use operating system commands to find the amount of remaining life in an NVMe device. Using the operating system commands The AIX, IBM i, and Linux operating systems have commands that you can use to determine the amount of life that is remaining in an NVMe device.
  • Page 113 Find information about using the IBM i operating system to find the amount of remaining life in an NVMe device. About this task To find the amount of remaining life in an NVMe device by using the IBM i operating system, complete the steps in this procedure. Procedure 1.
  • Page 114 Note: Failure of IBM NVMe devices is covered in the standard warranty and during the maintenance period only for devices that have not reached the maximum number of write cycles. Devices that reach this limit might fail to operate according to specifications and must be replaced. This replacement cost is not covered under the standard warranty or during the maintenance period.
  • Page 115 NVMe device at your earliest convenience. Note: Failure of IBM NVMe devices is covered in the standard warranty and during the maintenance period only for devices that have not reached the maximum number of write cycles. Devices that reach this limit might fail to operate according to specifications and must be replaced.
  • Page 116 102 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 117: Notices

    Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
  • Page 118: Accessibility Features For Ibm Power Systems Servers

    This product uses standard navigation keys. Interface information The IBM Power Systems servers user interfaces do not have content that flashes 2 - 55 times per second. The IBM Power Systems servers web user interface relies on cascading style sheets to render content properly and to provide a usable experience.
  • Page 119: Privacy Policy Considerations

    Contact the vendor for accessibility information about its products. Related accessibility information In addition to standard IBM help desk and support websites, IBM has a TTY telephone service for use by deaf or hard of hearing customers to access sales and support services:...
  • Page 120 Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 121 Tel: +49 (0) 800 225 5426 email: HalloIBM@de.ibm.com Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 / EN 55032 Klasse A. Japan Electronics and Information Technology Industries Association (JEITA) Notice This statement applies to products less than or equal to 20 A per phase.
  • Page 122 Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
  • Page 123: Class B Notices

    Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 124 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 110 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...
  • Page 125: Terms And Conditions

    Permissions for the use of these publications are granted subject to the following terms and conditions. Applicability: These terms and conditions are in addition to any terms of use for the IBM website. Personal Use: You may reproduce these publications for your personal, noncommercial use provided that all proprietary notices are preserved.
  • Page 126 112 Power Systems: PCIe adapters for the 9009-41A, 9009-42A, or 9223-42H...