About an output
The output can generate a falling edge, rising edge, toggle or continuous toggle.
Generate Falling Edge – generate a falling edge on the external GPO port if the present state of the
output is high. If the present state of the external GPO is low, no edge will be generated.
Generate Rising Edge – generate a rising edge on the external GPO port if the present state of the output
is low. If the present state of the external GPO is high, no edge will be generated.
Generate Toggle – generate a toggle on the external GPO port. If the present state of the output is low, a
rising edge will be generated, followed by a falling edge. If the present state of the output is high, a falling
edge will be generated, followed by a rising edge. Pulse width = 20 milliseconds.
Generate Continuous Toggle - This command will generate a continuous toggle of the external GPO
port. This toggle will continue until a Generate Falling Edge, Generate Rising Edge, or Generate Toggle
command is received. The rate of toggle is 24Hz. .
Output transistor
Maximum output driving voltage : V
Maximum current : I
max
Maximum power dissipation : 120 mW
Output from projector
VAC
M
Image B–2
When the GPO driver inside the projector becomes powerless the GPO state changes to the default
state. The default GPO state depends on the external system connected with the GPO port (pull-up
or pull-down circuitry).
GPIO and projector ECO mode
The Freya projector is equipped with an "ECO" mode, in which a minimum of features are available. Entering
or leaving ECO mode can be done with GPIO of the Cinema Controller via a predefined Macro (not editable).
However, this cannot be done with the GPIO of the ICMP-X.
The GPO signals of the ICMP will return to their default output level when the projector is switched to ECO
mode. This could generate unexpected "Falling Edge" triggers at the output pins. Also when awakening the
projector (from ECO mode to READY mode) the GPO signals of the ICMP may generate unexpected "Rising
Edge" events.
GPO and projector switching On or Off
The GPO signals of the Cinema Controller and ICMP will return to their default output level when the projector
is switched to OFF. This could generate unexpected "Falling Edge" triggers at the output pins. Also during
power-on the GPO signals may generate unexpected "Rising Edge" events.
B.2 Pin configurations of the communication ports
Ethernet port
Pin
Pair
Color
1
3
white/green
2
3
green
= 18 V
max
= 30 mA
Internal projector
V
max
R
GPOut P
Max 120 mW
GPOut N
10/100 Base-T — RJ45 port
Description
TXD+
TXD-
V+
R
1000 Base-T — RJ45 port
Description
TX0+
TX0-
R5910032 /00