Configuration - Media server automation
A Save as dialog is prompted.
10.
Enter a name for the cue and confirm with Save.
Click Save.

11.3.3 Devices and commands

Overview
Device type
Commands List
GPIO
PLAYER
Projector
TCP/UDP
(device)
JNIOR
222
R5910032 /00
Freya
Set output: to set one or more outputs to the desired value (0 or 1).
Pulse up: to realize a rapid change of amplitude of the output (0 to 1).
Pulse Down: to realize a rapid change of amplitude of the output (1 to 0).
Set Up: to set output to 1.
Set Down: to set output to 0.
Play: to start or resume the playback
Stop: to stop the playback
Pause: to pause the playback. The last played image remains on the screen. If the
'Duration in minutes' parameter is different than 0, the playback will automatically
resume after the given amount of time.
Pause (seconds): pause is defined in seconds
Resume: to resume a paused playback.
Enable Schedule: to enable the scheduled mode.
Disable Schedule: to disable the scheduled mode.
Emergency Stop: to disable the scheduled mode, stop the playback and trigger the "On
Emergency Stop" event.
Insert Show: to dynamically insert a show inside another main show in which the cue
was inserted. The insertion is done at selection time. Note that other actions in the cue
will be ignored.
Rewind (seconds): to rewind the defined time.
Play Scheduled Show: to start the playback of a scheduled show between scheduled
time and maximum delay.
Close Dowser: to close the dowser of the projector.
Open Dowser: to open the dowser of the projector.
Turn Lamp On: to turn the projector lamp on.
Turn Lamp Off: to turn the projector lamp off.
Execute Macro: to request macro execution by the projector. Macro selection from
macro list is necessary.
Send Text: to send a text command to the device. Special characters or delimiters have
to be replaced by the "\" character followed by the corresponding hexadecimal value on
two digits. For instance, the command can send the text "mute=0\0D\0A", where "\0D"
replaces the carriage return ("\r") and "\0A" replaces the new line ("\n").
Send Hex: to send a hex value to the device.
Send Binary: to send a binary value to the device.
Set outputs: to set one or more outputs to the desired value (0 or 1).
Pulse up: to realize a rapid change of amplitude of the output (0 to 1).
Pulse Down: to realize a rapid change of amplitude of the output (1 to 0).
Set Up: to set output to 1.
Set Down: to set output to 0.
Clear input counters: to clear counters for the given JNIOR input.
Clear input usage meter: to clear the usage meter for the given JNIOR input.
Clear output usage meter: to clear the usage meter for the given JNIOR output.
Reset input latch: to reset the given JNIOR input latch.
Execute Macro: to request a macro execution by the JNIOR. The macro name should
match the name of an existing macro on the JNIOR.