Safety
Restriction zone
To protect untrained users and children against high intensity light beams, the light beam Hazard Distance
(HD) shall be taken into account.

1.3 Important safety instructions

To prevent the risk of electrical shock
This projector should be operated from an AC power source. Ensure that the mains voltage and capacity
matches the projector electrical ratings. If you are unable to install the AC power requirements, contact
your electrician. Do not defeat the purpose of the grounding.
Installation should be done according to the local electrical code and regulations by qualified technical
personnel only.
This product is equipped with a 5-terminal barrier strip for the connection of a power line. The projector can
run on one of the following configurations, depending on what power system is available:
-
A 3W+N+PE power system (Y configuration).
-
A 3W+PE power system (Δ configuration).
-
A mono phase system with power line with a separate earth ground PE.
If you are unable to install the AC power requirements, contact your electrician. Do not defeat the purpose
of the grounding.
This product is equipped with a 3-terminal barrier strip for the connection of a UPS power cord (2-pole, 3-
wire grounding).
The electronics of the projector (UPS INLET) must be powered from a suitable UPS unit. The building has
to be provided with a circuit breaker of max 16A to protect the UPS.
The building installation has to be provided with a circuit breaker of max 40A to protect the complete unit.
The circuit breakers are considered as readily accessible disconnect devices that must be incorporated
externally to the equipment for removal of the power to the projector mains terminals and UPS inlet
terminals.
The cross-sectional area of the conductors in the power supply cord should be not less than 4 mm² (10
AWG) while using a circuit breaker of 40A max. The power cord should have a rating depending on what
power system is available:
-
Y configuration: min 500V.
-
Δ configuration: min 300V.
-
Mono phase configuration: min 300V.
The cross-sectional area of the UPS inlet cord shall be not less than 1.5 mm² (14 AWG) and has a rating of
minimum 300V.
In case of using a circuit breaker of a current rating less than 40A, the cross-sectional area of the
conductors in the power supply cord must comply with the local electrical code regulations where the
projector is installed.
The cable gland of the power supply cord has a clamping range between 11 mm and 21 mm ( cable
diameter of the power supply cord must be in this range :11-21 mm)
Disconnect the power to the projector mains terminals for removal of all power from the projector.
Do not allow anything to rest on the power cord. Do not locate this projector where persons will walk on the
cord.
Do not operate the projector with a damaged cord or if the projector has been dropped or damaged - until it
has been examined and approved for operation by a qualified service technician.
Position the cord so that it will not be tripped over, pulled, or contact hot surfaces.
If an extension cord is necessary, a cord with a current rating at least equal to that of the projector should
be used. A cord rated for less amperage than the projector may overheat.
Never push objects of any kind into this projector through cabinet slots as they may touch dangerous
voltage points or short circuit parts that could result in a risk of fire or electrical shock.
Do not expose this projector to rain or moisture.
Do not immerse or expose this projector in water or other liquids.
Do not spill liquid of any kind on this projector.
Should any liquid or solid object fall into the cabinet, unplug the set and have it checked by qualified
service personnel before resuming operations.
Do not disassemble this projector, always take it to an trained service person when service or repair work
is required.