TIP: Remove the MC fasteners so that the MC module can be raised to allow easy
access to disconnect and connect the
5. Remove the lift motor ground wire (GRN or GRN/YEL) from the frame chassis ground
screw fastener.
6. Remove the extension tube hitch pin and clevis pin fastener hardware from the lift plat-
form mounting bracket. Hold the lift platform while removing the clevis pin and care-
fully rest on the floor.
1
Input and Output Interface.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
1
I/O
connectors.
6 Replacement Procedures
Lift Motor Replacement
Page 204