The maintenance counter shows the remaining miles (or hours) until the machine main-
tenance is due. Reaching zero triggers the ASL pulsing blue "maintenance due" state.
Clearing the Blue Pulsing ASL State (Maintenance Counter reset)
Resetting the maintenance counter clears the blue pulsing ASL state and sets the ASL state
to solid blue. The maintenance counter is also reset to the default value (treadmills reset to
1000 miles, ellipticals reset to 250 Hrs).
P10, P30, P30i and P31 consoles:
1. Access Information Display (65).
2. Scroll to MAINT COUNTER > OK.
3. Press and hold down the QUICKSTART key (on the P30i, press down the START
key) for 3 secs or more until the maintenance counter is reset. The "HOLD TO RESET
MAINTENANCE COUNTER" message will show, and the maintenance counter is
reset to the default setting. The ASL state is reset to the blue solid state
P62, P80, and P82 consoles:
1. Access Service Settings (51765761) > Maintenance menu.
2. Select Next Maintenance Due > Reset.
Clearing the Yellow & Yellow Pulsing ASL states
An ASL pulsing yellow state is triggered when an error code event occurs and is logged. To
clear a pulsing yellow state, the error condition causing the ASL pulsing yellow must first be
resolved either manually or the machine may resolve and self-clear the issue. A manually or
machine self-cleared error code will change the ASL state from pulsing yellow to the solid
yellow state.
Clearing the pulsing yellow ASL state
An ASL pulsing yellow state is triggered when an error code event occurs and is logged. To
clear a pulsing yellow state, the error condition causing the ASL pulsing yellow must first be
resolved either manually or the machine may resolve and self-clear the issue. A manually or
machine self-cleared error code will change the ASL state from pulsing yellow to the solid
yellow state.
Clearing the solid yellow ASL state
P10, P30, P30i and P31 consoles:
On P10, P30, P30i and P31 consoles, clearing the error code from the Error Log resets the
ASL state from solid yellow to the solid blue state.
P62, P80, and P82 consoles:
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.