Removal Instructions
1. Switch the power OFF and unplug the power cord.
2. Remove the hood cover, see
3. Use a 5/16" hex key socket and ratchet to relax the running belt tension by alternately
loosening the left and right belt tension adjustment bolts in 1/4 turn increments. Use
this method to evenly remove the left and right belt tension. Do not use power tools
which can make it difficult to control the left/right 1/4 turn incremental bolt loosening
acquirement. Uneven belt tension removal can cause damage to the running belt or
tension adjustment hardware.
(missing or bad snippet)
4. Use a 1/2" socket with 6" extension to loosen the four Drive Motor mount bolts
enough so that the motor can slide forward and rearward in the mounting tray.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.