On/Off Sw Circuit Breaker Replacement; About - Precor Experience 700 Series Service Manual

Hide thumbs Also See for Experience 700 Series:
Table of Contents

Advertisement

ON/OFF SW Circuit Breaker Replacement

About

This procedure provides instruction to replace the ON/OFF SW Circuit Breaker.
The Power Entry Assembly located in the front of the treadmill under the frame weldment
cross member contains the Power Cord Inlet Assembly, the ON/OFF SW Circuit Breaker,
1
2
and the
ASL
PCA
these components.
ID
Power Entry Assembly Bracket
ON/OFF SW Circuit Breaker
1
Active Status Light: Service and maintenance status light.
2
Printed circuit assembly, generally referred to as either an upper PCA or lower PCA.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
board. The Power Entry Assembly Bracket must be removed to access
Description
Power Cord Inlet Assy
ASL PCA Board
6 Replacement Procedures
ON/OFF SW Circuit Breaker Replacement
Page 113