Ptx5000 Dc Power Supply Module; Table 17: Supported Power Distribution Units - Juniper PTX Series Hardware Manual

Packet transport switch
Hide thumbs Also See for PTX Series:
Table of Contents

Advertisement

Copyright © 2012, Juniper Networks, Inc.
Each 120-A DC power supply has the following components:
Four removable input power trays, labeled
power trays are hot-removable and hot-insertable. Each input power tray weighs 1.6
lb (0.7 kg).
Each input power tray has one input, labeled
its own 125-A circuit breaker located on the PDU above the input power tray.
LEDs to monitor the status of the power supply—
Twenty-one monitored electronic fuses for the fan trays, control boards, and FPCs.
NOTE:
There are no mechanical fuses in the PDU to be replaced. For output
voltage, current protection is provided by electronic fuses, hot-swap circuits,
or ORing circuit. Electronic fuses and hot-swap circuits also provide current
limitation.
NOTE:
The PDUs contain no fans, but are cooled by the fans in the power
supply modules.
PTX5000 PDU Load Sharing
When the packet transport switch is operating normally and both PDUs are switched on,
load sharing between them occurs automatically. When one PDU fails or is turned off,
the other PDU immediately assumes the entire electrical load for the system. A single
PDU can provide full power for as long as the packet transport switch is operational.

PTX5000 DC Power Supply Module

PSM Slots
The PTX5000 Packet Transport Switch has eight PSMs, located in the lower front of the
chassis below the FPC card cage. The PSMs insert into one of four slots—labeled
through
3
—located in the rear of each PDU labeled
PSM Function
The power supply modules provide voltage regulation and filtering. Each PSM produces
the output voltages, which are distributed by the PDUs.
PSMs Supported
The packet transport switch supports the PSM in

Table 17: Supported Power Distribution Units

Name
Model Number
DC PSM (120 A)
PSM-PTX-DC-120
Chapter 3: PTX5000 Hardware Components Overview
through
, from left to right. The input
0
3
and
, from left to right, and has
RTN
–48 V
,
PDU OK
–48 V 120 A
PDU0
and
PDU1
.
Table 17 on page
39.
First Supported Junos OS Release
12.1x48
, and
.
CB ON
0
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptx5000

Table of Contents