30
Vent Configuration: Vertical Termination
Vent configurations 20' or above (from the base of the fireplace) use 6-5/8" dia. vent.
Connect a 8" to 6-5/8" reducer directly to the fireplace (98900165).
NOTE: The included thimble assembly is not required and may be discarded.
The termination must fall within the shaded area shown in the chart. Use the indicated
restrictor positions.
Up to four elbows (45° or 90°) may be used. Only one horizontal elbow may be used.
40' (12m) max
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
Exhaust Restrictor # 6
Diffuser Open
15 feet (4.5m)
8" Vent
10 feet (3m)
5 feet (1.5m)
0 feet
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
© Travis Industries
Installation
Exhaust Restrictor # 9
Diffuser Open
6-5/8" Vent (place reducer on fireplace)
H1
(for qualified installers only)
Exhaust Restrictor # 4
Diffuser Open
8" Vent
H2
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is considered a
vertical elbow
1/2/19 - 1453
Exhaust Restrictor # 6
Diffuser Open
6-5/8" Vent (place reducer on fireplace)
Exhaust Restrictor # 4
Diffuser Closed (stock)
8" Vent
PB 72 MV/GSB2 Install
40' (12m) max
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet