Restore Default Values

This administrator-only hotkey restores the CS19208 / CS19216 default
values. see Factory Default Hotkeys and Settings, page 95. To restore the
default values, key in the following hotkey combination:
1. Invoke HSM with the [Num Lock] + [-] or [Ctrl] + [F12] combination.
2. Press [R].
3. Press [Enter].
After you press [Enter], the command line displays RESET TO DEFAULT
SETTING for one second; then the message disappears and you
automatically exit HSM.

Video DynaSync

Video DynaSync is ATEN's exclusive technology that eliminates boot-up
display problems and optimizes resolution when switching between ports. The
default setting is enabled. To invoke Video DynaSync, do the following:
1. Invoke HSM with the [Num Lock] + [-] or [Ctrl] + [F12] combination.
2. Press [D].
Note: If the monitor is disconnected and reconnected, the CS19208 /
CS19216 re-executes Video DynaSync.