An example of the connection of the open collector
OUT terminal (sink logic)
Output terminal setting
6
6.1.2
: Speed reach detection band
Function
[Parameter setting]
Parameter setting of designated frequency and detection band
Parameter setting of output terminal selection
Setting value 7 is reverse signal.
Note: Set to output to FLA-FLC-FLB terminals.
+24V
P24
OUT
Ry
NO
CC
Default outputs low-speed signal (ON signal) to OUT terminal. This setting must be changed to invert
the polarity of the signal.
[Parameter setting]
Title
Output terminal selection 1A (OUT)
Setting value 5 is reverse signal.
Set to output to FLA-FLC-FLB terminals.
Output of designated frequency reach signal
When the output frequency becomes equal to the setting by designated frequency , an ON
or OFF signal is generated.
Title
Function
Speed reach detection band
Title
Function
Output terminal
selection 1A
(OUT)
FLA
FLB
FLC
An example of the connection of the relay
output terminals
Function
Adjustment range
(Refer to section 10.6)
0.0 - (Hz)
Adjustment range
0-255
6: RCH (Output frequency attainment signal
(Refer to section 10.6)
F-2
+24V
RY
Default setting
4: LOW (Low-
0-255
speed detection
signal)
Adjustment range
Default setting
Setting
(acceleration/deceleration completed))