Linear Acceleration/Deceleration; S-Pattern Acceleration/Deceleration 1; S-Pattern Acceleration/Deceleration - Toshiba TOSVERT VF-nC3E Instruction Manual

Industrial inverter (for 3-phase induction motors)
Table of Contents

Advertisement

1) Linear acceleration/deceleration

Normal acceleration/deceleration
pattern.
Normally, this setting can be used.

2) S-pattern acceleration/deceleration 1

Used when necessary to accelerate or decelerate in a short period of time up to a high-speed area over 60
Hz, and to moderate shock at acceleration. Perfect for conveyance machinery.
Output frequency [Hz]
Max. frequency

Set frequency
0
Actual acceleration time

3) S-pattern acceleration/deceleration 2

Motor acceleration torque increases slowly in areas with a small weak magnetic field. Perfect for operation of
high-speed spindles.
Output frequency [Hz]
Max. frequency 
Set frequency
Base frequency
0

Actual acceleration time
Output frequency [Hz]
Max. frequency


Time [s]
Time [s]

F-47

0


Output frequency [Hz]
Max. frequency

Set frequency
0
Output frequency [Hz]
Max. frequency 
Set frequency
Base frequency
0
E6582233
Time [s]



Time [s]

Actual deceleration time
Time


[s]
Actual deceleration time
6