CAMSHAFT/CRANKSHAFT/ PISTON/CYLINDER
CONNECTING ROD BIG END I.D.
Set the connecting rod cap to the connecting rod. Be sure the
projections align properly.
Apply engine oil to the connecting rod bolt threads and seating
surface.
Tighten the connecting rod bolts to the specified torque.
TORQUE:
12 N•m (9 ft-lb)
Measure the connecting rod big end I.D.
STANDARD:
28.020 – 28.033 mm (1.1031 – 1.1036 in)
SERVICE LIMIT:
28.066 mm (1.1050 in)
If the measurement is more than the service limit, replace the
connecting rod and connecting rod cap.
CRANKSHAFT MAIN JOURNAL O.D.
Measure the crankshaft main journal O.D.
PTO side:
STANDARD:
27.980 – 27.993 mm (1.1016 – 1.1021 in)
SERVICE LIMIT:
27.933 mm (1.0997 in)
Flywheel side:
STANDARD:
25.380 – 25.393 mm (0.9992 – 0.9997 in)
SERVICE LIMIT:
25.333 mm (0.9974 in)
If the measurement is less than the service limit, replace the
crankshaft.
CRANKPIN O.D.
Measure the crankpin O.D. of the crankshaft.
STANDARD:
27.970 – 27.980 mm (1.1012 – 1.1016 in)
SERVICE LIMIT:
27.920 mm (1.0992 in)
If the measurement is less than the service limit, replace the
crankshaft.