A Sensor Trouble Restore Report is sent for Burglary
Zones when the zone is resealed or the next time the
system is disarmed (whichever happens first). A 24-
Hour Zone sends a restore signal only when it is
resealed.
The Trouble code parameter has no effect on
Contact ID Format because a Sensor Trouble Report
is always reported as Event Code 380.
If Sensor Trouble Reports are not
required, program Locations 387 and 388
as 0.
15.5
Zone Status – Sensor Watch
Reports
Location
389 to 390
Sensor Watch Report
Sensor Watch Restore Report
A Self Test Failure Report (Contact ID Event Code
307) is sent to the base station receiver when a zone
was not activated during the Sensor Watch Time
programmed in Locations 476 and 477 (refer to
Section 15.5 Zone Status – Sensor Watch Reports on
page 78). This report continues to be sent (according
to the frequency of the Sensor Watch Time) until the
fault is corrected.
To clear the fault and stop any additional reporting,
you must unseal and reseal the zone that registered
the fault. Use the Sensor Watch Time in Locations
476 and 477 to set the number of days a zone can
remain sealed without registering a fault. Refer to
Section 14.3.5 Zone Options 1 on page 61 to select
zones to be monitored by the Sensor Watch feature.
If Self Test Failure Reports are not
required, program Locations 389 and 390
as 0.
15.6
Zone Status – Alarm Restore Code
391
Location
14
Default
If Zone Alarm Restore Reports are required,
program this location as 14. If not, program this
location as 0.
Location 392 (Section 15.7 Zone Status Reporting Options
on page 66) is ignored when programming the Alarm
Restore code and is global for all zones. A zone
Restore Report is sent only to the receiving party to
which the zone is allocated (for example, Receiver 1
or Receiver 2).
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
System Reporting Information
15.7
Location
0
1
2
4
8
This location is set by default to report only to
Receiver 1. You can select whether Zone Status
Reports are sent to Receiver 1, Receiver 2, or both,
Receiver 2 only when Receiver 1 fails, or no
reporting.
For a partitioned ICP-CC488 Control Panel, this
location is ignored if Option 1 is selected in Location
501 (refer to Section 19.3.2 Partitioning Options 2 on
page 85).
Location
Default
15.8
389
4
390
5
Location
Default
0
1 to 15
An RF Supervision Failure Report (Contact ID Event
Code 307) is sent to the base station receiver when
the wireless receiver has not received a signal from
any RF wireless zone during the RF Supervision
Time. This report continues to be sent (according to
the frequency of the RF Supervision Time) until the
fault is corrected.
To clear the fault and stop additional reporting:
Unseal and reseal the zone that registered the fault.
Refer to Section 3.13 Fault Descriptions on page 18 for
more information.
15.9
Location

RF Low Battery Report

RF Low Battery Restore Report
An RF Low Battery Report (Contact ID Event Code
384) is sent to the base station receiver when the
battery voltage on a wireless zone falls below
approximately 2.4 VDC. An RF Low Battery Restore
Report is sent on the first valid signal after the
battery is replaced.

15.10 RF Receiver Trouble Report

Location
Tens digit
Units digit

Zone Status Reporting Options

392
No zone status reports allowed
Report to Receiver 1
Report to Receiver 2
Report to both Receiver 1 and Receiver 2
Report to Receiver 2 only if Receiver 1 fails

RF Supervision Time

393
0
Disable RF Supervision Time Reports
Increments of 6 hours (0 to 90 hours)
If RF Supervision Failure Reports are not
required, program Location 393 as 0.
RF Low Battery Report
394 to 395
396 to 397
EN | 66
Location
Default
394
6
395
8
Location
Default
396
7
397
9