Comparison Table Of Cable Option Combinations; Changes From Mr-J3 Series To Mr-J4 Series - Mitsubishi Electric MELSERVO-J3 Series Handbook

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

Part 8: Review on Replacement of Optional Peripheral Equipment

3. COMPARISON TABLE OF CABLE OPTION COMBINATIONS

3.1 Changes from MR-J3 series to MR-J4 series

Application
Encoder cable
Encoder connector set
SSCNET optical communication
cable
Connector set for SSCNET optical
communication
Junction terminal
General-
block cable
Purpose
connector set
Interface
Junction terminal
CN1
block
Junction terminal
SSCNET
block cable
Interface
CN3
connector set
Servo motor power supply cable
Power connector set
(Servo motor side power
connector)
Electromagnetic brake cable
Electromagnetic brake connector
set
Cable option combinations
MR-J3 series
MR-J3ENCBL_M-A_-_
MR-J3JCBL03M-A_-L
MR-EKCBL_M-_
MR-J3JSCBL03M-A_-L
MR-J3ENSCBL_M-_
MR-ENECBL_M-H
MR-ENECBL_M-H
MR-ENECBL_M-H-MTH
MR-ECNM
MR-J3SCNS
MR-J3SCNSA
MR-ENECNS
MR-J3BUS_M
MR-J3BUS_M-_
MR-J3BCN1
MR-J2M-CN1TBL_M
MR-J3CN1
MR-TB50
MR-J2HBUS_M
MR-CCN1
MR-PWS1CBL_M-A_-_
MR-PWS2CBL03M-A_-L
MR-PWCNS4
MR-PWCNS5
MR-PWCNS3
MR-PWCNS1
MR-PWCNS2
MR-BKS1CBL_M-A_-_
MR-BKS2CBL03M-A_-L
MR-BKCNS1
MR-BKCNS1A
MR-BKCN
8 - 12
Compatibility
MR-J4 series
(Note 6)
(Note 1)
MR-J3SCNS
(Note 1)
MR-ENECNS
(Note 1)
MR-ENCNS2
MR-J3SCNSA
MR-ENCNS2A
MR-BKCNS1
MR-BKCNS2
MR-BKCNS1A
MR-BKCNS2A
Note
Use the same combination.
_M: Cable length
A_: Leading direction
-_: Bending life
Use the same cables for the
models other than the ones
shown below.
It is required when using 15
kW or more HG-JR 1000
r/min series or 22 kW or
more HG-JR 1500 r/min
series.
_: Cable length
Use the same combination.
Use the same cables for the
models other than the ones
shown below.
It is required when using 15
kW or more HG-JR 1000
r/min series or 22 kW or
more HG-JR 1500 r/min
series.
The screw-type is added.
Use the same combination.
The screw-type is added.
Use the same combination.
Use the same combination.
_M: Cable length
-_: Bending life
Use the same combination.
Use the same combination.
_: Cable length
Use the same combination.
Use the same combination.
Use the same combination.
_: Cable length
Use the same combination.
Use the same combination.
_M: Cable length
A_: Leading direction
-_: Bending life
Use the same combination.
Use the same combination.
_M: Cable length
A_: Leading direction
-_: Bending life
Use the same combination.
The screw-type is added.
Use the same combination.
The screw-type is added.
Use the same combination.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents