Part 5: Review on Replacement of MR-J3-DU_ with MR-J4-DU_
MR-J3-CR55K/MR-J3-CR55K4
No.
Name and function
PA09
Alarm history clear
Used to clear the alarm history.
0 0 0 x:
Alarm history clear
0: Invalid
1: Valid
When alarm history clear is made valid, the alarm
history is cleared at next power-on.
After the alarm history is cleared, the setting is
automatically made invalid (reset to 0).
PA12
Input filter setting
Select the input filter.
0 0 0 x:
Input signal filter
If external input signal causes chattering due to noise,
etc., input
filter is used to suppress it.
0: None
1: 1.777 [ms]
2: 3.555 [ms]
3: 5.333 [ms]
PA15
For manufacturer setting
Do not change this value by any means.
Initial
No.
value
0000h
PA09
Alarm history clear
Used to clear the alarm history.
_ _ _ x:
0: Disabled
1: Enabled
When you select "Enabled", the alarm history will be
cleared at next power-on. After the alarm history is
cleared, the setting is automatically disabled.
_ _ x _:
For manufacturer setting
_ x _ _:
For manufacturer setting
x _ _ _:
For manufacturer setting
0002h
PA12
Input filter setting
Select the input filter.
_ _ _ x:
If external input signal causes chattering due to noise,
etc., input filter is used to suppress it.
0: None
1: 1.777 [ms]
2: 3.555 [ms]
3: 5.333 [ms]
_ _ x _:
For manufacturer setting
_ x _ _:
For manufacturer setting
x _ _ _:
For manufacturer setting
0000h
PA15
Function selection A-3
_ _ _ x:
Selection of unit power consumption display unit
0: increment of 1 kW
1: increment of 0.1 kW
_ _ x _:
For manufacturer setting
_ x _ _:
For manufacturer setting
x _ _ _:
For manufacturer setting
5 - 39
MR-CR55K/MR-CR55K4
Name and function
Initial
value
0h
0h
0h
0h
2h
0h
0h
0h
0h
0h
0h
0h