Removing An Fmd96 - Juniper TCX1000-RDM20 Hardware Manual

Programmable roadm
Hide thumbs Also See for TCX1000-RDM20:
Table of Contents

Advertisement

Removing an FMD96

Copyright © 2019, Juniper Networks, Inc.
You have successfully completed this procedure.
Use this procedure to remove the FMD96 from a rack.
Tools Required
Number 2 Phillips screwdriver (for ground screw)
Number 2 Robertson screwdriver or hex wrench (for fasteners that attach the module
to the frame)
Antistatic bag
NOTE:
Be familiar with the site, safety, and installation guidelines described
in Module Installation and Removal Guidelines.
Open the hinged front cover and disconnect the fibers.
1.
CAUTION:
When working with the FMD96, follow the safety procedures
associated with equipment containing Laser Safety Hazard Level 1M.
CAUTION:
When the ports are optically connected, the module is capable
of passing light from all client and line ports at all times. The client and
line port connections must be limited to Class 1M (21.3 dBm) Laser Safety
Regulations.
Disconnect the ground cable. See
2.
Loosen the ground screw and remove the lug and ground cable. Secure the ground
screw again.
Chapter 16: Installing and Connecting the FMD96 Modules
Figure 39 on page 102
101