Monitoring Points; 96-Channel Fixed Mux/Demux Specifications - Juniper TCX1000-RDM20 Hardware Manual

Programmable roadm
Hide thumbs Also See for TCX1000-RDM20:
Table of Contents

Advertisement

Monitoring Points

96-Channel Fixed Mux/Demux Specifications

Table 33: FMD96 (BT8A78MD03) Specifications
Parameters
Physical
Width
Height
Depth
Weight
Environmental
Temperature and Humidity
Power Consumption
Optical
Central Wavelengths (C-band)
Number of Channels (50-GHz spacing)
Insertion Loss (client in to line out)
Insertion Loss (line in to client out)
1
Monitor In Port Loss
2
Monitor Out Port Loss
L1 Composite Input Signal Power
Client Input Signal Power
Copyright © 2019, Juniper Networks, Inc.
The FMD96 provides diagnostic equipment (connected to the MON port), monitoring
access to internal blocks.
In the line-in direction, the monitoring point is at the input to the demultiplexing stage
after the OSC signal has been extracted. In the line-out direction, the monitoring point
is at the output of the multiplexing stage before the OSC signal is multiplexed back in.
See
Table 33 on page 95
for the FMD96 specifications.
Range
438 mm
88 mm
280 mm
See Site Requirements.
Not applicable, passive
Minimum
1528.77 nm
4.0 dB
4.0 dB
19.6 dB
17.9 dB
Chapter 16: Installing and Connecting the FMD96 Modules
Typical
Maximum
1566.72 nm
96 channels
6.5 dB
6.5 dB
22.3 dB
21.2 dB
23 dBm
5 dBm/port
3
95

Advertisement

Table of Contents
loading

Table of Contents