Ground Wire - Stihl MS 441 Manual

Hide thumbs Also See for MS 441:
Table of Contents

Advertisement

– Press grommet (2) in until it
completely encloses the opening.
1
: Lay the short circuit wire (1) flat in
the guides (arrows).
Press the short circuit wire home in
the guides with a narrow, blunt tool.
– Ensure that the short circuit wire
is correctly located in the guides
during the further assembly work.
– Reassemble in the reverse
sequence.
– Tightening torques, b 3.5.
66
9.6.3

Ground wire

Functioning of the short circuit wire,
as well as of the heaters in
machines with handle heating, may
be impaired or made impossible by
a faulty ground wire.
The ground wire must be removed
and tested for contact and
continuity.
– Remove filter base, b 14.1.2.
– Pull out switch shaft,
b 12.1.
– Remove carburetor support,
b 14.6.1.
: Disconnect ground wire (1) from
contact spring (arrow).
: Take out screw (arrow).
– Remove and examine ground
wire (1), replace if necessary.
: Fit ground wire (1) and support
eyelet at supporting rib (2).
: Fit screw (3) and tighten it down.
– Reassemble all other parts in the
reverse sequence.
1
Machines with handle heating
2
1
: Disconnect ground wire (1) from
contact spring (2) and terminal
socket (3).
1
1
3
MS 441, MS 441 C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents