Inlet Needle - Stihl MS 441 Manual

Hide thumbs Also See for MS 441:
Table of Contents

Advertisement

– Note installation sequence for
metering diaphragm (2) and
gasket (1).
: Position gasket (1) and metering
diaphragm (2) in the pegs
(arrows), ensuring that the tab (3)
faces towards the adjusting
screws.
: Position cover (1) so that the
connector (arrow) faces towards
the choke shutter and is secured
by the pegs.
102
2
1
3
Machines with handle heating
: Fit switch (1).
: Insert screws (arrows) and
tighten them down.
– Check that diaphragm and
gasket are correctly seated, then
tighten screws cross-wise.
– Reassemble all other parts in the
reverse sequence.
1

14.4.3 Inlet needle

1
– Remove metering diaphragm,
b 14.4.2.
: Take out screw (arrow).
: Pull inlet control lever (1) with
spindle (2) out of the groove in
the inlet needle.
The spring under the inlet control
lever may pop out.
1
: Pull out inlet needle (1).
– Remove and examine spring (2),
replace if necessary.
2
1
2
MS 441, MS 441 C

Hide quick links:

Advertisement

Table of Contents
loading