Ground Wire; Contact Spring - Stihl MS 311 Manual

Hide thumbs Also See for MS 311:
Table of Contents

Advertisement

2
: The ring terminal (1) must locate
behind the lug (2).
1
– Fit the contact spring, b 7.7.4
: Push the ground wire (1) into the
guide (arrow).
– Install the ignition lead, b 7.3
– Reconnect the choke rod,
b 10.2.1
– Reassemble all other parts in the
reverse sequence.
46
7.7.3

Ground Wire

A faulty ground wire may impair or
prevent operation of the short circuit
1
wire.
The ground wire is combined with
the short circuit wire in a wiring
harness. If damaged, the wiring
harness must be replaced
– Check for contact and continuity
and
replace the wiring harness,
b 7.7
7.7.4

Contact Spring

– Remove the shroud, b 6.4
– Remove the choke rod,
b 10.2.1
2
: Move the switch shaft (1)
towards the tank housing until the
contact spring (2) is free.
: Lift the contact spring (1) over the
lug (arrow) and pull it out.
– Check the ground wire ring
terminal and replace it if
necessary, b 7.7.3
Installing
– Place the contact spring (1) in
position at a slight angle.
1
: Push the contact spring (1) onto
the pins (arrows) as far as stop.
1
1
MS 311, MS 391

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms 391

Table of Contents