The size of the tolerance windows is set with machine data of the FS. Reaching of the
synchronism is influenced by the following factors:
● AV, DV: Position variance between FS and LS
● VV: Difference in speed between FS and LS
Figure 19-3
Axes and spindles
Function Manual, 06/2019, A5E47437747B AA
1
0
Synchronism monitoring with COUPON and synchronism test mark WAITC with
synchronization on a turning leading spindle
S3: Synchronous spindle
19.1 Brief description
863