(64) Needle cooler control
Function No. : 109
Item : 1 Whether needle cooler control is provided or not is set.
OFF
Indication
ON
Item : 2 Output destintion of needle cooler is set.
0
Indication
1 to 16
(65) Heat-wire thread trimming control : Not used with the standard sewing machine.
Function No. : 110
Item : 1 Whether heat-wire thread trimming control is provided or not is set.
OFF
Indication
ON
Item : 2 Input terminal of thread trimming completion signal is set.
0
Indication
1 to 16
(66) Setting of the feeding frame operation timing
Function No. : 111
Item : 1 Delay time after output of feeding frame lowering signal is set.
0 to 999 X 1 mS [Contents] Delay time from output of feeding frame lowering signal to lowering
Indication
Item : 2 Setting of feeding frame lowering sensor : Not used with the standard machine.
0 to 999 X 1 mS [Contents] Sensor to securely detect lowering of the feeding frame is used and the
Indication
(67) Setting of needle thread tension disk floating control
Function No. : 112
Item : 1 Whether solenoid operation is provided or not is set.
OFF
Indication
ON
Item : 2 Delay time setting (ON)
Indication
0 to 999 X 1 mS [Contents] Delay time before operating the solenoid is set. : Initial setting : 100 mS
Item : 3 Delay time setting (OFF)
0 to 999
Indication
Function : Needle cooler control is set.
[Contents] Output signal for solenoid valve is not transmitted : Initial setting
[Contents] Output signal for solenoid valve is transmitted.
[Contents] No connection : Initial setting
[Contents] Output terminal for solenoid valve is set.
Function : Heat-wire thread trimming control.
[Contents] Heat-wire thread trimming control is not performed. : Initial setting
[Contents] Heat-wire thread trimming control is performed.
[Contents] No connection : Initial setting
[Contents] Input terminal is set.
Function : Timing after the feeding frame has come down is set.
of intermediate presser is set. Initial setting : 170 mS
(If the setting is 170 mS or less, the intermediate presser may come
in contact with the feeding frame.)
delay time when the machine is actuated is set. : Initial setting : 500 mS
Function : Setting of disk floating solenoid (optional) control
[Contents] No output : Initial setting
[Contents] Output is performed.
[Contents] Delay time from completion of solenoid operation to the next control
is set. : Initial setting : 0 mS