(41) Feeding frame connection setting 1 : This function is not used with the standard machine.
Function No. : 063
Item : 1 Setting of the feeding frame 1
0
1 to 16
Indication
Item : 2 Setting of the feeding frame 2
0
1 to 16
Indication
Item : 3 Setting of the feeding frame 3
0
1 to 16
Indication
(42) Feeding frame connection setting 2 : This function is not used with the standard machine.
Function No. : 064
Item : 1 Setting of the feeding frame 4
0
Indication
1 to 16
Item : 2 Chuck sensor setting
0
Indication
1 to 16
Item : 3 Setting of the output at the time of start
LOW
Indication
HIGH
Function : Setting of the output device of the drive signal of feeding frame
[Contents] No connection
[Contents] Output of the feeding frame is set to the terminal number. By this
setting, the signal output device of the feeding frame 1 can be freely
changed. : Initial setting 1
[Contents] No connection
[Contents] Output of the feeding frame is set to the terminal number. By this
setting, the signal output device of the feeding frame 2 can be freely
changed. : Initial setting 2
[Contents] No connection : Initial setting
[Contents] Output of the feeding frame is set to the terminal number. By this setting,
the signal output device of the feeding frame 2 can be freely changed.
Function : Setting of the output device of the drive signal of feeding frame
[Contents] No connection : Initial setting
[Contents] Output of the feeding frame is set to the terminal number. By this setting,
the signal output device of the feeding frame 4 can be freely changed.
[Contents] No connection : Initial setting
[Contents] Set to the chuck sensor input terminal number. By this setting, the
signal input device of the chuck sensor can be freely changed.
[Contents] Active LOW output (When the power is ON, the feeding frame goes
up when the feeding frame signal is in the low level.) : Initial setting
[Contents] Active HIGH output (When the power is ON, the feeding frame
goes up when the feeding signal is in the high level.)
75
(Set level 2)
(Set level 2)
(Set level 2)
(Set level 2)
(Set level 2)
(Set level 2)