Function No. 98 Pedal input control (3)
Setting of pedal operating method is performed.
Item 1 : Pedal operation active of the pedal 1 (feeding frame, right) is set.
Set value : LOW/HIGH Intial setting
Item 2 : Pedal operation active of the pedal 2 (feeding frame, left) is set. (Pneumatic type only)
Set value : LOW/HIGH Initial setting : LOW
Item 3 : Pedal operation active of the pedal 3 (stroke presser) is set.
Set value : LOW/HIGH Initial setting : LOW
(Not used with LK-1930.)
Function No. 99 Pedal input control (4)
Pedal operating method is set.(Continuation of the function No. 99 is set.)
Item 1 : Pedal operation active of the pedal 4 (stroke presser 2) is set.
Set value : LOW/HIGH Initial setting : LOW
(Not used with LK-1930.)
Item 2 : Pedal operation active of the pedal 5 (start) is set.
Set value : LOW/HIGH Initial setting : LOW
[Description of operation of each setting]
Setting (active)
LOW
HIGH
Contact of the pedal switch operates at the time of "open → close".
Contact of the pedal switch operates at the time of "close → open".
Description