(24) Intermediate presser control
Function No. : 035
Item : 1 Intermediate presser control
SEW
TRIAL
Indication
OFF
Item : 2 Lowering timing
START
Indication
O. PRSR
(25) Wiper control
Function No. : 036
Item : 1 Operation mode setting : Normally, use at the standard setting.
OFF
Indication
Mg
AIR
Item : 2 Sweeping position setting
UNDER
Indication
BETWEEN
Item : 3 Sweeping position setting 2
UDET
AUDET
Indication
(26) Thread clamp control : This function is not used with the standard LK-1930.
Function No. : 037
Item : 1 Thread clamp control
OFF
Indication
ON
Item : 2 Thread clamp release operation timing
0 to 15
Indication
Function : Setting of the intermediate presser operation mode
[Contents] Intermediate presser is operative. (The intermediate presser comes
down by the sewing data when the machine runs.) : Initial setting
[Contents] Intermediate presser is operative. (The intermediate presser comes down
by the sewing data both when the feed goes forward and backward.)
[Contents] Intermediate presser is inoperative and fixed at the lifting position.
(Set level 2)
[Contents] The intermediate presser is lowered immeadiately before the sewing
machine starts. (The intermediate presser is lowered when the
sewing machine starts rotating.) : Initial setting
[Contents] The intermediate presser is lowered simultaneously with the feeding
frame. (The intermediate presser comes down simultaneously when
the last feeding frame of the sequence of feeding frame is lowered.)
Function : Wiper operation mode setting
[Contents] Wiper operation is rendered ineffective.
[Contents] Signal of the magnet type wiper is rendered effective. : Initial setting
[Contents] Signal of the pneumatic type wiper is rendered effective.
[Contents] Below-sweeping (Wiper sweeps below the intermediate presser.) : This
function is operative when the optional side-sweeping wiper is used.
[Contents] Above-sweeping (Wiper sweeps above the intermediate presser.)
: Initial setting
[Contents] Wiper sweeps when the needle bar stops up.: Initial setting.
[Contents] Wiper sweeps when the needle bar stops at the upper dead point.
It is possible when the main shaft stop position is set to its upper dead
point.
Function : Wiper operation mode setting
[Contens] The thread clamp is made inoperative. : Initial setting
[Contens] The thread clamp is made operative.
[Contens] The number of stitches to be sewn, from the state where the thread
clamp retains the needle thread to the point at which it releases the
thread, is specified. : Initial setting 0
70
(Set level 1)
(Set level 1)
(Set level 2)
(Set level 2)
(Set level 2)
(Set level 2)
(Set level 2)

Hide quick links: