JUKI LK-1910 Engineer's Manual page 76

Computer-controlled high speed bar tacking industrial sewing machine, computer-controlled high speed bar tacking industrial sewing machine with input function
Hide thumbs Also See for LK-1910:
Table of Contents

Advertisement

(27) Thread breakage detector control
Function No. 038
Item : 1 Device control
OFF
Indication
ON
Item : 2 Setting the number of stitches required to stop the machine (at the sewing start)
0 to 15
Indication
Item : 3 Setting the number of stitches required to stop the machine (during normal operation)(Set level 2)
0 to 15
Indication
(28) Air pressure drop detecting control
Function No. : 039
Item : 1 Detecting operation mode setting
OFF
Indication
ON
(29) Material end detection control : This function is not used with the LK-1930.
Function No. : 040
Item : 1 Detection control
OFF
Indication
ON
Remarks : Input terminal number is set with the function No. 74.
(30) Tension controller No. 3 optional control
Function No. : 041
Item : 1 Device control
OFF
Indication
ON
Function : Thread breakage detector operation mode setting
[Contents] The thread breakage detecting device is ineffective.
[Contents] The thread breakage detecting deviceon effective. Initial setting
[Contents] When thread breakage or slip-off of the thread occurred at the
sewing start, the number of stitches required to stop the sewing
machine from the detection to the stop is set. : Initial setting 8
[Contents] The number of stitches required to stop the sewing machine after
the detection of thread breakage during normal operation is
specified. : Initial setting 3
Function : Air pressure drop detector setting
[Contents] The air pressure drop detecting function is rendered ineffective.
(Magnet type initial setting)
[Contents] The air pressure drop detecting function is rendered effective.
(Pneumatic type initial setting)
Function : Material end detector setting
[Contents] The material end detection function is rendered ineffective. : Initial setting
[Contents] The material end detection function is rendered effective.
Function : Setting of the tension controller No. 3
[Contents] The tension controller No. 3 control is rendered ineffective.
[Contents] The tension controller No. 3 control is rendered effective. : Initial setting
71
(Set level 1)
(Set level 2)
(Set level 2)
(Set level 2)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lk-1920Lk-1930

Table of Contents