C3-1: Source For Pulse Input Is Open-Collector Npn Type Equipment; C3-2: Source For Pulse Input Is Open-Collector Pnp Type Equipment - Delta ASDA-A3 Series User Manual

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
You can input the Pulse command with the open-collector or line driver. The maximum input
pulse for the line driver is 4 mpps and 200 kpps for open-collector.
C3-1: the source for the pulse input is open-collector NPN type equipment, which uses the
external power supply.
Note: this is not supported by the A3-F.
C3-2: the source for the pulse input is open-collector PNP type equipment, which uses the
external power supply.
Controller
Note: this is not supported by the A3-F.
Revision December, 2017
Controller
+
DC
24V
-
SG
+
24V
-
SG
Servo Drive
35
Pull-hi_S
1.5 KΩ
Max. pulse input frequency:
S
51 Ω
51 Ω
37
/S
39
Pull-hi_P
Max. pulse input frequency:
1.5 KΩ
51 Ω
P
51 Ω
41
/P
Servo Drive
35
Pull-hi_S
1.5 kΩ
Max. pulse input frequency:
51 Ω
S
51 Ω
37
/S
Pull-hi_P
39
Max. pulse input frequency:
1.5 kΩ
51 Ω
P
51 Ω
41
/P
200 kpps
200 kpps
200 kpps
200 kpps
Wiring
3
3-31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents