When The Screen Displays; Overvoltage Warning; Encoder Error Warning - Delta ASDA-A3 Series User Manual

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

Trial Operation and Panel Display

When the screen displays

4

Overvoltage warning:

This means the voltage input from the main circuit is higher than the rated range or a power
input error has occurred (incorrect power system).
Corrective action:
1.
2.
When the screen displays

Encoder error warning:

Check that the motor encoder is securely connected and the wiring is correct.
Corrective action:
1. Make sure the wiring is following the instructions in the user manual.
2. Check the encoder connector.
3. Check for loose wiring.
4. Check for damage to the encoder.
4-16
Use the voltmeter to measure the input voltage from the main circuit, and ensure it is
within the rated range.
Use the voltmeter to check if the power system complies with the specifications.
ASDA-A3