Parameters
P1.019
Default:
8
Unit:
Format:
Settings:
U
X
Y
X: additional function for Capture
Bit
Bit
1 – 3
Z: additional function for Compare
Bit
Bit
0
1 – 3
P1.020
Default:
Unit:
Format:
Settings:
When the Capture function is enabled and set to capture multiple points (P5.038 > 1), the system stops
receiving the DI captured signal within this range once the data is captured. The DI captured signal
received within this range is not recognized as valid. Use this function to avoid the system seeing noise
as effective signals within the non-capture range. The masking range is defined as follows: (CAP_DATA
– P1.020, CAP_DATA + P1.020).
8-38
Capture / Compare additional function settings
0x0000
-
HEX
Z
Y
X
Additional function for Capture
Reserved
3
2
1
0
Function
Set this bit to 0 to disable this function.
Set this bit to 1 to enable this function.
Cycle
0
mode
If enabled, the E-Cam alignment correction is conducted when
DI.ALGN is on.
Reserved
-
3
2
1
0
Function
Set this bit to 0 to disable this function.
P1.024 is
Set this bit to 1, and P1.024 is reset to 0 automatically,
reset to 0
automatically
but it only takes effect once.
Reserved
-
Capture - Masking range
0
Pulse unit of capture source
DEC
Control mode: ALL
Setting range: 0x0000 – 0x0101
Data size:
16-bit
Z
Additional function for Compare
U
Reserved
Description
Description
Control mode: ALL
Setting range: 0 – 100000000
Data size:
32-bit
ASDA-A3
Address: 0126H
0127H
Address: 0128H
0129H