P2.034
Default:
5000
Unit:
rpm
Format:
DEC
Settings:
In Speed mode, this parameter sets the acceptable difference between the command speed and the
feedback speed. If the difference is greater than this value, AL007 occurs.
P2.035
Default:
50331648
Unit:
pulse
Format:
DEC
Settings:
In Position mode, this parameter sets the acceptable difference between the command position and the
feedback position. If the difference is greater than this value, AL009 occurs.
P2.036
Default:
0x0000
Unit:
-
Format:
HEX
Settings:
Please refer to the description of P2.010.
P2.037
Default:
0x0000
Unit:
-
Format:
HEX
Settings:
Please refer to the description of P2.010.
P2.038
Default:
0x0000
Unit:
-
Format:
HEX
Revision December, 2017
Speed command error warning
Excessive deviation of Position command warning
DI9 functional planning
DI10 functional planning
VDI11 functional planning
Control mode: S / Sz
1 – 30000 (rotary motor)
Setting range:
1 – 15999 (linear motor)
Data size:
16-bit
Control mode: PT / PR
Setting range: 1 – 1677721600
Data size:
32-bit
Control mode: All
Setting range: 0 – 0x015F (last two codes are
DI codes)
Data size:
16-bit
Control mode: All
0 – 0x015F (last two codes are
Setting range:
DI codes)
Data size:
16-bit
Control mode: All
Setting range: 0 – 0x015F (last two codes are
DI codes)
Data size:
16-bit
Parameters
Address: 0244H
0245H
Address: 0246H
0247H
Address: 0248H
0249H
Address: 024AH
024BH
Address: 024CH
024DH
8-71