Editing Components In The Device View - Siemens SINAMICS S120 Commissioning Manual

With startdrive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

3. Drag a non-specified infeed unit from the hardware catalog into the device view in the
light gray area of the existing infeed unit.
Figure 4-10
Then specify the infeed unit connected in parallel (refer to Chapter "Specifying an infeed
unit (Page 89)").
4. Repeat step 3 to connect additional infeed units in parallel.
Result
The infeed unit connected in parallel is inserted and specified. The white area turns gray.
The infeed units are linked with one another via interfaces X201 and X200.
Note
If required, parallel connection can be activated or deactivated for individual infeed units via
the Inspector window (Line Module_xx/drop-down list "Component activation").
Disconnect individual infeed units from the line supply (e.g. using a contactor) to deactivate
these. Motor supply cables must be opened.
4.4.5.4

Editing components in the device view

Editing components
The various components are displayed graphically in the device view.
Commissioning with Startdrive
Commissioning Manual, 12/2018, 6SL3097-5AA10-0BP0
Connect the infeed in parallel
4.4 Creating a project offline in Startdrive
Commissioning
93