3. In order to parameterize the device supply voltage, click the
data/operating mode" entry.
The "Line data/operating mode" screen form opens:
Figure 4-16
Set the desired device supply voltage here (see chapter "Line data/operating mode
(Page 168)").
Make the other entries depending on the infeed type.
If you have used a Basic Line Module (BLM) or Smart Line Module (SLM) as infeed unit,
then here, the detailed settings have now been completed. However, if you are using an
ALM, then proceed as follows:
4. if you are using a different line filter than the pre-selected line filter, select the desired line
filter in the drop-down list with the same name (p0220[0]).
5. If you are using an AIM line filter for the booksize format, you can also activate a pre-
selected Basic Line Filter.
In this case, select the "Basic Line Filter booksize ..." (p0220[1]) option.
Result
You have made the detailed settings for the infeed of your device configuration.
Commissioning with Startdrive
Commissioning Manual, 12/2018, 6SL3097-5AA10-0BP0
Example: Line data/operating mode for ALM