Closing The Brake - Siemens SINAMICS S120 Commissioning Manual

With startdrive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Commissioning
4.11 Configuring brake control
Figure 4-74
1. Interconnect the "Unconditionally open holding brake" (p0855) signal sink for the
command to open the brake unconditionally.
The brake opens when this signal or the internal signal "Open brake" has the value "1".
Note
The "Unconditionally close holding brake" signal has a higher priority than the
"Unconditionally open holding brake" signal.
4.11.2.4

Closing the brake

To assign the parameters that influence the closing of the brake, proceed as follows:
Figure 4-75
226
Simple brake control: Open brake
"Drive axis > Parameter > Drive functions > Brake control > Close brake"
Simple brake control: Close brake
Commissioning with Startdrive
Commissioning Manual, 12/2018, 6SL3097-5AA10-0BP0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents